Go to documentation repository
Documentation for ACFA PSIM 1.3.
Associating AIM input with terms allows changing the value of an internal variable's term at certain events.
Associating AIM input with terms is performed on the settings panel of the Apollo AIM Input object. The object is created on the basis of the Apollo AIM Reader object.
Associating AIM input with a term is performed as follows:
- Go to the settings panel of the Apollo AIM Input object.
- From the Internal variable drop-down list, select the required Apollo Internal Variable object (1).
- From the IV term drop-down list, select the Apollo Term object corresponding to a term to be controlled by the state of this Apollo AIM Input object (2).
From the drop-down lists in the Operation with term, if group, select which values the term should have if the AIM input is not configured, armed, in a fault state or in an alarm (3). The following operations are available:
Operation
Description
No operation
The value of the corresponding term does not change
Clear term
The term is set to FALSE
Set term
The term is set to TRUE
Send impulse
The value of the term changes to the opposite for a short preset period
- Click the Apply button.
- To save the changes to the controller, write configuration to hardware.
Associating AIM input with a term is completed.