Go to documentation repository
Previous page Next page
To configure the numbers of the Axxon PSIM SIP-terminal, do the following:
The Subscriber column (2) lists the numbers of all devices and operators registered on the SIP-terminal, as well as special numbers.
The Name field (3) lists the names of the corresponding devices, operators, and special numbers.
In the Redirecting field (4), enter the number to which the corresponding subscriber's calls must be forwarded. You can specify several numbers separated by a semicolon. In this case, redirection is performed on all specified devices and operators. Thus, the group call is created.
Attention!
We highly don't recommend setting the redirection of subscribers to yourself, that is, specifying the same number in the Redirecting field as in the Subscriber field. In this case, the system can operate incorrectly. If you try to save the settings of the subscriber redirection to yourself, the warning window is displayed:
To clear the Redirecting field of subscribers with the incorrect setting, click the No button. To proceed with the configuration without changes, click the Yes button.
In the Pending, sec field (5), enter the time period in seconds during which you must wait for a response from the subscriber. If you don't specify the value in the field, this value is set by the CallTimeout registry key and by default is 30 sec (see Registry keys reference guide). If you specify a value greater than in the CallTimeout key, then it isn't applied, that is, the lowest value specified in the Pending, sec field and the CallTimeout key is used as a timeout.
From the Run macro drop-down list (7), select the Macro object, which must be run when you call the subscriber. See also Creating and configuring Macro events and Macros for working with SIP-terminal.
In the Calling user multicast (sound) / Calling user multicast (video) fields (8), specify the IP address for broadcasting the video stream and audio stream from the calling device in the "multicast" mode.
Configuring the numbers of the Axxon PSIM SIP-terminal is complete