Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

To configure the Hands up detection, do the following:

  1. Create Pose Detection (see Configuring the Pose Detection).
  2. Below the Pose Detection, click Create…  Hands up detection.

By default, the Hands up detection triggers if there is a person with both hands raised in a specified area.

If necessary, you can change the detection tool parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe detection tool is enabled by default. To disable the detection tool, select the No value
No
Name Hands up detectionEnter the detection tool name or leave the default name
TypeHands up detectionName of the detection tool type (non-editable field)
Basic settings
ModeBoth handsSelect this value if you want the detection tool to trigger only when a person has both hands raised
One handSelect this value if you want the detection tool to trigger only when a person has either left or right hand raised
Only leftSelect this value if you want the detection tool to trigger only when a person has one selected hand raised
Only right
Left handSelect this value if you want the detection tool to trigger only when a selected hand is raised
Right hand
Number of measurements in a row to trigger detection2

Specify the minimum number of frames with a person with a hand/hands raised for the detection tool to trigger. The value must be in the range [1, 20].
The recommended (default) value is 2.
Increasing the value can help eliminate false alarms, but increases the risk of skips. 
Decreasing the value can help reduce skips, but increases the probability of false alarms

Note

  • The Hands up detection works in the areas for detection and skip areas specified in the Pose Detection (see Configuring the Pose Detection).
  • For convenience of configuration, you can "freeze" the frame. Click the button. To cancel the action, click this button again.
  • The area for detection is displayed by default. To hide it, click the button. To cancel the action, click this button again.

To save the parameters of the detection tool, click the Apply  button. To cancel the changes, click the Cancel  button.