New integration modules
- Hartmann Odyssey, ACS. Hartmann Odyssey software version 3.1.0.73 is integrated. The main functionality is receiving access events with information about the user who accessed. Control of access points is also implemented, including the ability to temporarily open doors.
- Honeywell, FSA. VISTA-128BPT panel is integrated. The main functionality is receiving alarm events from monitored zones united into partitions. Control of zones is implemented, including the ability to enable alarm bypass mode and the ability to control partitions with arming and disarming functions supporting multiple arming modes.
- Peridect+, PID. CUP+, LCP+, DSP+, LIP+ devices of all versions are integrated. The main functionality is receiving and processing alarm events from detectors grouped into segments. Control of detectors, groups, and segments, including arming and disarming, and alarm processing is implemented.
- BacNet Server, universal protocol. The main functionality is data communication and data processing between Axxon One + ACFA and BACnet devices.
New features and improvements
- SALTO: ProAccess SPACE: updated the version of ProAccessSpace software to 6.10.3.1.
- OPC UA:
- Added quality for tags:
- Good: indicates that the data or operation is successful and the data is valid;
- Bad: indicates that there is a problem with the data or operation. Data can be unavailable or unreliable;
- Uncertain: indicates that the data can be unreliable or its quality cannot be guaranteed.
- Added parameters to events: name of the parent object and name of the child object from which the event was received;
- Now you can create duplicate child objects below parent objects;
- Added the Use source time parameter that allows you to use the time of the OPC server;
- Improved the algorithm of OPC server polling;
- Added the SamplingInterval (ms) parameter for the variable, numeric variable, and group of items. This parameter ensures the stability of event reception.
- Added quality for tags:
- SNMP Agent:
- Improved interface;
- Fixed an error related to changing the value of the polling interval for OID (object identifier).
- ZKTeco: PUSH SDK:
- Added events that indicate limitations on the amount of biometric data that you can add to the device;
- Added new types of verification that are written only to the intermediate database of the device;
- Corrected control commands and the state of the Door ZK PUSH object.
New features and improvements of the service integration modules
- Added new object types;
- Fixed problems related to control;
- Updated events about command execution results.