Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.

Previous page Setting up the Web-server module to act as a gate on a different HTTP-server  Counting the system events Next page


The RTSP Server object is used for transmitting video from Server to remote workplaces using the RTSP protocol. Use of the RTSP protocol allows viewing video from IP cameras and video archive on remote clients by means of the Intellect software or using video players that support this protocol. Transmitting Video gate archive and Backup archive is also supported.

Attention!

Transmitted video stream is to be compressed using H.264, H.265, MPEG4 or MJPEG codecs.

When MJPEG codec is in use, video of height and/or width more than 2048 pixels is not supported.

Only live video is supported for H.265 codec.

To view the archive via RTSP Server, the archive should be recorded in the same codec. Otherwise, the archived video will not play.

It is to be taken into account that while configuring each RTSP Server loads only one CPU core. To increase the number of RTSP streams several RTSP Server objects are to be created and configured on several cameras. 

Create and configure the RTSP Server object as follows:  

  1. In the context menu of the Computer object select Create object => RTSP Server.
  2. Specify the name and ID of the object in the opened panel.
  3. Click the Apply button to create the object.
  4. Open the settings panel for the RTSP Server object. For this select the created object in the Intellect objects tree.
  5. In the Cameras table set the checkboxes next to video cameras video from which is to be displayed (1). If camera has several streams, the default stream is broadcasted.

    Note.

    If default stream is changed on the corresponding Camera object settings panel after applying RTSP Server settings, it is mandatory to click Apply on the RTSP Server object settings panel to apply changes to it as well. See also Configuration of multistream video.

    Note.

     To select several cameras at the same time, mark lines in the table and then holding down the Ctrl key on the keyboard click the unchecked box in one of the marked lines.

    As a result all selected lines will be set checked.
    To uncheck several boxes at the same time, do the same, but click the checked box after the selection of the lines.
  6. If video from the camera is to be received through the video gate, then select the Vide ogate object in the Gate drop-down list (2). 
  7. In the RTSP port field specify the port via which the video is transmitted (3).

    Note.

    The "Windows Media Player Network Sharing"  service can use the default port 554. Change the port number or disable this service for translation.

    To disable the service go to the Control panel - Administrative Tools - Services and double-click on the service name and click the Stop button in the opened window.

  8. In the HTTP port field specify the port that is to be used for transmitting video via http-protocol (4).
  9. To distribute transmitted signal among different RTSP-ports set the Multicast checkbox (1). In the Cameras table the Port column is displayed. Every video camera is to have a data transmission port (2).

    Important!

    The following ports are in use for each camera in the Multicast mode: nPort, nPort + 18000 (rtp), nPort + 19000 (rtcp), where nPort – port number specified for camera in the Port column.
    For proper operation of RTSP server in the Multicast mode these ports are to be vacant.


    Note.

    Use of the Multicast mode allows decreasing Server load due to reduction of transmitted data.

    Note.

    In spite of specifying video data port it is required to specify camera number in source address (see table below).

    Note.

    To get such video in the Intellect software (see Configuring multimedia receipt using RTSP protocol) set the multicast value to the RTSP parameter in the HKEY_LOCAL_MACHINE \SOFTWARE\ITV\Intellect\Video\TransportProtocols registry section (for 64-bit system the path is HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ITV\Intellect\Video\TransportProtocols) on computer where the Camera object is created. Detailed information on this parameter see in Changing the transport protocol used by IP-device section.

  10. In the Receiver IP address field enter the address from which the broadcast in Multicast mode will be performed. Address is to be in range from 224.0.0.0 to 239.255.255.255 (3). By default, the receiver IP is 224.0.1.150.

    Important!

    224.0.0.0-224.0.0.255 address range is reserved for routing protocols and other protocols. Destination IP address cannot be set from the specified range.

    Note.

    RTSP-server can broadcast to one network simultaneously. The network with minimal metric is selected on default. To change the broadcast network, create the IpInterface = "IP-address of required interface" key in the registry. See also Registry keys reference guide.

  11. If the current time is to be sent to VLC Media Player instead of the frame time, then Go to the Advanced settings tab and set the VLC player compatibility mode checkbox (1). This option is to be used in case of problems when playing back the archive received over RTSP in VLC Media Player.

    Note

    Until Intellect 4.10.3 (including), the send_real_time registry key was used instead of the VLC player compatibility mode checkbox  - see Registry keys reference guide.

  12. If the RTSP Server is used for broadcasting the video data to the Single Data Center (ECHD), and the Video Surveillance Servers are behind NAT, then it is necessary to specify the NAT settings:

    1. In the IP address field, specify the IP address of the router that performs the NAT broadcasting (2).

    2. In the Port field, specify the port of the router, which is accessed by the client when executing the Single Data Center (ECHD) requests (3).

      Note

      To enable the substitution of the router's specified IP address and port to the Single Data Center (ECHD) requests, it is necessary to set the corresponding checkbox in the settings panel of the Web server object - see Enabling the processing of ECHD requests and selecting rtsp server.

  13. Click the Apply button to save the changes.

The RTSP Server object is now configured.

To connect to Server and display video in the video player that supports RTSP protocol, specify the address of data source in the format given in the table.

Address

Example

Description

rtsp://Server IP address[:Port]/CameraNo.

 

rtsp://192.168.0.3/1

Viewing video signal from Camera 1 if default port is in use.

rtsp://224.0.0.3:555/1

Viewing video signal from Camera 1 when broadcasting in Multicast mode if port 555 is in use for video transmission from this camera.

rtsp://Login:Password@Server IP address[:Port]/CameraNo.rtsp://login:pass@192.168.0.1:554/1Viewing video signal from Camera 1 if users and permissions are configured in Intellect software (see Rights administration).

rtsp://Server IP address[:Port]/archive?id= CameraNo.&time_begin=yyyy.mm.dd-hh:mm:ss&&time_end= yyyy.mm.dd-hh:mm:ss

rtsp://192.168.0.3:554/archive?id=1&time_begin=2011.11.11-11:11:11&&time_end=2011.11.11-11:12:00

Viewing video archive from Camera 1 for specified time period .

rtsp://Server IP address[:Port]/archive?id=CameraNo.&time_begin=yyyymmddThhmmssZ&time_end=yyyymmddThhmmssZrtsp://192.168.15.182:555/archive?id=1&time_begin=20160331T080000Z&time_end=20160331T080800ZViewing video archive from Camera 1 for specified time period
rtsp://Server IP address[:Port]/archive?id=CameraNo.&time_begin=yyyymmddThhmmssZrtsp://192.168.15.182:555/archive?id=4&time_begin=20160316T065000Z

Viewing video archive from Camera 4 from specific start time till the archive end (as the value of time_end is not specified in the address).

rtsp://Server IP address[:Port]/archive?id=CameraNo.rtsp://192.168.15.182:555/archive?id=4Viewing video archive from Camera 4 from the beginning till the end.
rtsp://Server IP address[:Port]/archive?id=CameraNo.&long_term_archive=BackupArchiveNo.rtsp://10.0.12.60:559/archive?id=1&long_term_archive=2Viewing Camera 1 video archive from Backup archive 2.
rtsp://archive?id=CameraNo.&gate=VideogateNo.rtsp://10.0.12.60:559/archive?id=1&gate=3Viewing Camera 1 video archive from Video gate 3.

Note.

If 554 port is in use (default value,) it can be not specified in the address line.

If captions are overlaid on the video (see Configuring captions display on a video image), they will be transmitted via RTSP server along with the video and can be displayed in the receiving app – VLC player.

Note.

Correct video and captions operation are enabled only in VLC Media Player 2.0.0. These features are not guaranteed to work in other versions of VLC Media Player or other programs.

  • No labels