Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page The Report window  Connecting to databases Next page


The OptionsForm settings window allows specifying additional parameters for the Report system: archive viewing mode, database connection, etc. To open the OptionsForm window, click the Settings button in the Report window (see The Report window section).

Figure shows the OptionsForm window.

The OptionsForm window includes the following interface elements (numbered according to the screenshot in the figure):

  1. Archive View Mode group allows selecting the mode of playing the recordings from the video archive in the Report system:
  2. The RealTime radio-button activates the playback via the viewing window of the Intellect system.

    Note.

     This option is available if the Intellect software is currently running on the server where the archive is stored.
  3. The With Converter radio-button activates the playback via the Converter.exe program.
  4. The Protocol group allows to select the data exchange protocol for the connection with the videoserver:
    1. TCP/IP protocol;
    2. X.25 protocol .

      Note.

      This protocol is used in the ATM-Intellect system (banking machine surveillance system).
  5. The Protocol in Separate DB checkbox allows connecting a separate event database.

    Note.

    This checkbox should be checked if the table with the registered events (the PROTOCOL table) is stored in a separate database outside of the Intellect system.
  6. The Protocol’s DB Name field allows to select the name of the database.
    To select the database, click the "...” button. The Data Link Properties window will open. Specify the database type, its pathname and access parameters (similar to changing the current database of the Report system).

    Note.

    This field is enabled if the Protocol In Separate DB checkbox is checked.
  7. The Connection Time field sets the waiting time for the connection with the videoserver.
  8. The IIDK_ID field sets the id of the IIDK Interface object in the system settings. This object is used to receive the video feed from surveillance cameras of the ATM-Intellect system via the X.25 protocol.
  9. The Frames Amount field sets the total number of frames requested from the videoserver when working via the X.25 protocol.
  10. The Msec Between Frames field sets the time delay in milliseconds between the frames received from the banking machine archive. This parameter helps decrease the traffic in the communications channels working via the X.25 protocol.