Running of SL USBIO 16x8 card drivers in Windows can take up to 10 minutes. To reduce this time to 2 minutes, use the utility to configure the USB device sensor/relay SL USBIO 16x8 − it can be downloaded at AxxonSoft website.
Set a lower value of the TimeOut PowerUp parameter for each device in this utility (recommended value is 10-20 seconds). The utility does not provide the ability to select a specific device, so you should connect one SL USBIO 16x8 device in turn, disconnecting others.
Axxon PSIM is to be started after running drivers of SL USBIO 16x8 devices (you can control the status of the drivers via the Windows Device Manager).
If auto start of Axxon PSIM is configured using the Auto Startup feature in Windows, then configure the delayed start of Axxon PSIM at least 2 minutes after the operating system reboots.
If Axxon PSIM starts as a Windows wrapper, safe operation of the SLIO USBIO 16x8 card is not guaranteed in Axxon PSIM. In this case, select another way to start Axxon PSIM (see Configuring system startup and shutdown section in Administrator's Guide).
The Relay objects corresponding to relays connected to SL USBIO (4x4, 16x8 and 24x4) card are created under the Video Capture Device objects of the SL USBio type.
When configuring the Relay objects one is to specify the channel numbers of relay connection to the card. Channels are numbered according to external pinout of the card (see Appendix 5. Electrical and technical specifications of Sensor-Relay cards).
To change the channel numeration, use the Channel Number list on the settings panel of the Relay object.
The Sensor objects corresponding to sensors connected to SL USBIO (4x4, 16x8 and 24x4) card are created under the Video Capture Device objects of the SL USBio type.
When configuring the Sensor objects one is to specify the channel numbers of sensor connection to the card. Channels are numbered according to external pinout of the card (see Appendix 5. Electrical and technical specifications of Sensor-Relay cards).
To change the channel numeration, use the Channel Number list on the settings panel of the Sensor object.