Configuring Lilin PIH-800III telemetry control panel

Configure the Lilin PIH-800III telemetry control panel in the Axxon PSIM as follows:

  1. Create the Telemetry controller object.
    1. Configure the Telemetry controller object as follows:
    2. Specify the Lilin PIH-7000/7600 communication protocol.

      Note.

      In order to transmit directly data to Lilin cameras connected via a serial port, select the Lilin PIH-7000/7600 Direct communication protocol. However, the full functionality of these cameras can be used, even what is not supported by Axxon PSIM.

    3. In the Port list, specify the number of the serial (COM) port for connecting to the telemetry controller.
    4. Specify 9600 value for the Rate parameter.
    5. Specify None value for the Parity parameter.
    6. Set the DTR and RTS checkboxes checked.
  2. Create the Control panel object under the Telemetry controller object.
  3. Configure the Control panel object as described in Telemetry control panel configuration section.

Lilin PIH-800III telemetry control panel is now configured in Axxon PSIM.

Using Lilin PIH-800III telemetry control panel

Some of Lilin PIH-800III telemetry control panel's keys correspond to standard functions in Axxon PSIM.

Note.

The functionality of these keys is also described in the reference documentation on Lilin PIH-800III control panel.

Key

Function

ZOOM IN / ZOOM OUT

Increases/decreases the size of the image

FOCUS FAR / FOCUS NEAR

Increases/decreases the focal distance of the lens

IRIS O / IRIS C

Opens/closes the aperture

AUTOFOCUS

Sets the focal distance of the lens automatically

AUTOIRIS

Automatically selects the position of the aperture

AUTOPAN

Switches the pan head to auto-pan mode; or switches a dome camera to auto-patrol mode

PRESET

Switches to a preset; saves a preset

PRESET 1/2/3/4

Switches to preset 1/2/3/4

Some of Lilin PIH-800III control panel's keys can be used through the KEY_PRESSED event. Axxon PSIM receives the KEY_PRESSED event when these keys are pressed on Lilin PIH-800III telemetry control panel's keyboard.

Event

Message

Parameter

Description

KEY_PRESSED

A key was pressed

param0

Code the key that was pressed

 The source of this event is the Control panel object (TELEMETRY_EXT). The event's documentation indicates the code of the key that was pressed (param0). The key code for entering a number (1, 2, or 4 digits) is equal to the number entered. A four-byte hexadecimal code is used for function keys.

Key

Code

Hexadecimal code

ESC

1769472

0x001B0000

LIGHT

655360

0x000A0000

CTRL1

851969

0x001A0000

CTRL2

851970

0x00090000

CLR

3604480

0x00370000

ENT

3538944

0x00360000

WIPER

786432

0x000C0000

SPRAY

720896

0x000B0000

No messages are sent to Axxon PSIM when the F1-F4, MON and CAM keys are pressed.

Control panel functions associated with the execution of actions in Axxon PSIM when events arrive from the control panel can be implemented using the following resources:

  1. Scripts written in the JScript programming language (see The Script object. Programming using the JScript language for more information on how to create scripts);
  2. Programs written in internal programming language in Axxon PSIM;
  3. Macros (see Creating and using macros in Administrator's Guide for more information).