Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Operator query panel object  The Settings panel of the Videogate object Next page


The Alarm Message Window object is used to display an interface box with the text message about alarm events that were initiated by the Axxon PSIM digital video surveillance system.

The settings panel of the Alarm Message Window object is shown in the figure.

Table describes the setting parameters corresponding to the elements of the settings panel of the Alarm Message Window object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Alarm Message Window object in the digital video surveillance system with the distributed architecture

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Alarm Message Window objects in the digital video surveillance system with the distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Alarm Message Window object in the digital video surveillance system with the distributed architecture

Latin, Cyrillic and service characters

Alarm Message Window

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Alarm Message Window object in the digital video surveillance system with the distributed architecture

Boolean type

Clear

Set—the Alarm Message Window object is disabled and isn't used

Clear—the Alarm Message Window object is enabled and used

4

Computer

Select the value from the list

Sets the Computer parent object of the digital system with the distributed architecture, to which the given Alarm Message Window object belongs

Name of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture

5

X

Enter the value into the field

Sets the coordinate in the horizontal X axis of the upper left corner of the Alarm Message Window on the screen

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed Video Monitors

6

Y

Enter the value into the field

Sets the coordinate in the vertical Y axis of the upper left corner of the Alarm Message Window on the screen

% of the screen height

Not defined

From 0 to M*100, where M is the number of the installed Video Monitors

*Name of the element isn't displayed in the settings panel of the given object.