Go to documentation repository
The Alarm Message Window object is used to display an interface box with the text message about alarm events that were initiated by the Axxon PSIM digital video surveillance system.
The settings panel of the Alarm Message Window object is shown in the figure.
Table describes the setting parameters corresponding to the elements of the settings panel of the Alarm Message Window object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Alarm Message Window object in the digital video surveillance system with the distributed architecture | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Alarm Message Window objects in the digital video surveillance system with the distributed architecture |
2 | Name* | Enter the value into the field | Sets the name of the Alarm Message Window object in the digital video surveillance system with the distributed architecture | Latin, Cyrillic and service characters | Alarm Message Window | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (enabled or disabled) of the Alarm Message Window object in the digital video surveillance system with the distributed architecture | Boolean type | Clear | Set—the Alarm Message Window object is disabled and isn't used Clear—the Alarm Message Window object is enabled and used |
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture, to which the given Alarm Message Window object belongs | Name of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture |
5 | X | Enter the value into the field | Sets the coordinate in the horizontal X axis of the upper left corner of the Alarm Message Window on the screen | % of the screen width | Not defined | From 0 to M*100, where M is the number of the installed Video Monitors |
6 | Y | Enter the value into the field | Sets the coordinate in the vertical Y axis of the upper left corner of the Alarm Message Window on the screen | % of the screen height | Not defined | From 0 to M*100, where M is the number of the installed Video Monitors |
*Name of the element isn't displayed in the settings panel of the given object.