Go to documentation repository
The Backup archive panel object is used to register and configure the Backup archive panel interface object in Axxon PSIM, which allows the Operator to configure video data archiving.
The settings panel of the Backup archive panel object is shown in the figure.
Table describes the setting parameters corresponding to the elements of the settings panel of the Backup archive panel object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Backup archive panel | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Backup archive panel objects in the digital video surveillance system with distributed architecture |
2 | Name* | Enter the value into the field | Sets the name of the Backup archive panel object | Latin, Cyrillic and service characters | Backup archive panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state of the Backup archive panel object | Boolean type | Clear | Set—the Backup archive panel object is disabled and isn't used Clear—the Backup archive panel object is enabled and used |
4 | Display | Select the value from the list | Sets the Display parent object of the digital system with distributed architecture, to which the given Backup archive panel object belongs | Name of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the digital video surveillance system with distributed architecture |
5 | Backup archive* | Select the value from the list | Sets a Backup archive, which the Operator will control using the Backup archive panel interface object | Name of the Backup archive objects registered in the system | Backup archive 1 | Depends on the number of the Backup archive objects in the digital video surveillance system with distributed architecture |
6 | Fixed position | Set the checkbox | Allows moving the Backup archive panel on the screen using the mouse | Boolean type | Clear | Set—the Backup archive panel cannot be moved Clear—the Backup archive panel can be moved |
7 | X | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the X coordinate in the horizontal axis for the upper left corner of the Backup archive panel on the screen | % of the screen width | Not defined | From 0 to M*100, where M is the number of the installed monitors |
8 | Y | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the Y coordinate in the vertical axis for the upper left corner of the Backup archive panel on the screen | % of the screen height | Not defined | From 0 to M*100, where M is the number of the installed monitors |
9 | W | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the width of the Backup archive panel | % of the screen width | Not defined | From 0 to M*100, where M is the number of the installed monitors |
10 | H | Enter the value into the field (Automatically, if the Fixed position checkbox is set) | Sets the height of the Backup archive panel | % of the screen width | Not defined | From 0 to M*100, where M is the number of the installed monitors |
*Name of the element isn't displayed in the settings panel of the given object.