The Backup archive panel object is used to register and configure the Backup archive panel interface object in Axxon PSIM, which allows the Operator to configure video data archiving.

The settings panel of the Backup archive panel object is shown in the figure.

Table describes the setting parameters corresponding to the elements of the settings panel of the Backup archive panel object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Backup archive panel

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Backup archive panel objects in the digital video surveillance system with distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Backup archive panel object

Latin, Cyrillic and service characters

Backup archive panel

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state of the Backup archive panel object

Boolean type

Clear

Setthe Backup archive panel object is disabled and isn't used

Clearthe Backup archive panel object is enabled and used

4

Display

Select the value from the list

Sets the Display parent object of the digital system with distributed architecture, to which the given Backup archive panel object belongs

Name of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the digital video surveillance system with distributed architecture

5

Backup archive*

Select the value from the list

Sets a Backup archive, which the Operator will control using the Backup archive panel interface object

Name of the Backup archive objects registered in the system

Backup archive 1

Depends on the number of the Backup archive objects in the digital video surveillance system with distributed architecture

6

Fixed position

Set the checkbox

Allows moving the Backup archive panel on the screen using the mouse

Boolean type

Clear

Setthe Backup archive panel cannot be moved

Clearthe Backup archive panel can be moved

7

X

Enter the value into the field

(Automatically, if the Fixed position checkbox is set)

Sets the X coordinate in the horizontal axis for the upper left corner of the Backup archive panel on the screen

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

8

Y

Enter the value into the field

(Automatically, if the Fixed position checkbox is set)

Sets the Y coordinate in the vertical axis for the upper left corner of the Backup archive panel on the screen

% of the screen height

Not defined

From 0 to M*100, where M is the number of the installed monitors

9

W

Enter the value into the field

(Automatically, if the Fixed position checkbox is set)

Sets the width of the Backup archive panel

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

10

H

Enter the value into the field

(Automatically, if the Fixed position checkbox is set)

Sets the height of the Backup archive panel

% of the screen width

Not defined

From 0 to M*100, where M is the number of the installed monitors

*Name of the element isn't displayed in the settings panel of the given object.