Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Videogate object  The Settings panel of the Data replication service object Next page


The Event counter object is used to register and count events of a certain type, occurring at the specified objects and registered by Axxon PSIM.

The settings panel for the Event counter object is shown in the figure.

Table describes the setting parameters corresponding to the elements of the settings panel of the Event counter object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Event counter object in the digital video surveillance system with the distributed architecture

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Event counter objects in the digital video surveillance system with the distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Event counter object in the digital video surveillance system with the distributed architecture

Latin, Cyrillic and service characters

Event counter

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Event counter object in the digital video surveillance system with the distributed architecture

Boolean type

Clear

Set—the Event counter object is disabled

Clearthe Event counter object is enabled

4

Computer

Select the value from the list

Sets the Computer parent object of the digital system with the distributed architecture, to which the given Event counter object belongs

Name of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture

The Start to count group

5

From (activation)

Set the checkbox

Allows setting manually the date and time of the count start



Boolean type

Set

Set—the date and time of the count start are set manually

Clear—the date and time of the count start are set at the date and time, when the Event counter object was last modified

From (date)

Enter the value into the field or select the value from the drop-down list

Sets the date of the count start

DATE:MONTH:YEAR

Current system date

09.1752 – 12.9999

From (time)

Enter the value into the field

Sets the time of the count start

HOURS:MINUTES:SECONDS

Current system time

00:00:0 – 23:59:59

6

From the moment counter settings are changed

Set the checkbox

Sets the date and time of the count start at the date and time, when the Event counter object was last modified

Boolean type

Clear

Set—the date and time of the count start are set at the date and time, when the Event counter object was last modified

Clear—the date and time of the count start are set manually

7

One counter for all events

Set the checkbox

Sets the same counter for all events presented in the Objects and events group of the given Event counter object

Boolean type

Set

Set—only one counter will be used for counting all events specified in the Objects group

Clear—different events are counted by different counters (each event is counted by a separate counter)

The Signal group

8

By time (activation)

Set the checkbox

Enables regular notification in a set period of time


Boolean type

Set

Set—the notification by time is enabled

Clear—the notification by time is disabled (notification by quantity of events is enabled)

By time (every)

Enter the value into the field

Sets the notification period as a time interval. Notification is performed regardless of count start time at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day, depending on the time unit settings)

Sequence of numbers

0

0 2147483648

By time (time unit)

Select the value from the list

Sets a time unit for the notification

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a regular notification about events starting from the set one

Boolean type

Clear

Set—the notification by quantity of events is enabled

Clear—the notification by quantity of events is disabled (the notification by time is enabled)

By quantity of events (quantity of events)

Enter the value into the field

Sets the number of event starting from which the notification will be performed.

Example: if the parameter has the value 5, then notification will be performed by every event starting from 5 (5, 6, 7, 8, etc.)

Sequence of numbers

0

0 2147483648

The Reset counters group

9

By (activation)

Set the checkbox

Enables a cyclic counter reset in a set time period



Boolean type

Set

Set—a cyclic reset in a set time period is enabled

Clear—a cyclic reset in a set time period is disabled (By quantity of events (a cyclic reset by quantity of events is enabled)

By (every)

Enter the value into the field

Sets a reset period as a time interval.

Reset is performed regardless of the time of the count start at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day, depending on the time unit settings)

Sequence of numbers

0

0 2147483648

By (time unit)

Select the value from the list

Sets a time unit for the counters reset

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a counter reset when it reaches a specified number of event


Boolean type

Clear

Set—a cyclic reset upon reaching a specified number of events is enabled

Clear—a cyclic reset upon reaching a specified number of events is disabled (a cyclic reset by time is enabled)

By quantity of events (quantity of events)

Enter the value into the field

Sets a reset period for counters by quantity of events

Sequence of numbers

0

0 2147483648

The Objects and events group

10

Object's type

Select the value from the list

Sets the type of object for which the events are counted

Names of the types of objects registered in the system

Not set

Depends on the types of objects registered in the digital video surveillance system with the distributed architecture

ID

Select the value from the list

Sets the identification number of an object of the selected type for which the events are counted

Sequence of numbers

Not set

Depends on the number of objects of the given type in the digital video surveillance system with the distributed architecture

Object name

Automatically

Displays the identification number of the selected object

Latin, Cyrillic and service characters

Not set

Object name with the specified identifier

11

Event

Select the value from the list

Sets an event that should be counted

Latin, Cyrillic and service characters

Not set

Depends on the types of objects registered in the digital video surveillance system with the distributed architecture

*Name of the element isn't displayed in the settings panel of the given object.