Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Data replication service object  The Settings panel of the Backup audio archive object Next page


The Failover service object is used to ensure the operation of the distributed system in the failover mode.

The settings panel of the Failover service object is shown in the figure.

Table describes the setting parameters corresponding to the elements of the settings panel of the Failover service object.

 

Parameter

 

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Monitor PC

Select the value from the list

Sets the name of the Server the state of which will be monitored by the object

Names of the Computer objects registered in the system

-

Depends on the number of the Computer objects registered in the system

2

Speed ​​of object transfer to monitoring computer (rpm)

Enter the value into the field

Sets the speed of transferring objects in case the connection is lost. This setting is necessary so that the failover server sends messages at a certain speed and the receiving server has time to process them. The transfer speed should be set depending on the network speed, server bandwidth, etc.

Sequence of numbers

1000

From 0 and above

3

Wait for reconnection (s)

Enter the value into the field

Sets the time period in seconds after which the configuration will be transferred to the backup Server after the loss of connection

Sequence of numbers

-

From 0 to 65535

4Time left __ days

Automatically

Displays the period of time in days remaining to restore the configuration from the backup Server to the main Server and restore the license

Days

0.00

From 0.00 to 50.00

5Transfer if no pingSet the checkboxSpecifies if it is necessary to transfer the configuration without the ping from the main monitored ServerBoolean typeClear

Set—the configuration is transferred if there is no ping

Clear—ping isn't taken into account when transferring the configuration

6

Type

Select the value from the list

Sets the object type in the configuration of the monitored Server that should be transferred to the backup Server in case of connection loss

Types of objects registered on the basis of the main Server

-

Depends on the configuration created on the basis of the main Server

7

Number

Select the value from the list

Sets the identifier of the object of the selected type that should be transferred to the backup Server in case of connection loss

Identifiers of the objects of the selected type that are present in the configuration of the monitored Server

-

Depends on the number of the objects of the selected type in the configuration of main Server

8

Name

Automatically

Sets the name of the object that should be transferred to the backup Server in case of connection loss

Names of the objects of the selected type that are present in the configuration of the monitored Server

-

Depends on the configuration created on the basis of the main Server

9

Range

Click the button

Opens the dialog box for the complex selection of the monitored objects

-

-

-