Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Security zone object  The Settings panel of the Program object Next page


The Macro object is used to support the automatic execution of a pre-defined sequence of commands upon occurrence of certain events, registered by Axxon PSIM.

The settings panel of the Macro object is shown in the figure.

Table describes the setting parameters corresponding to the elements of the settings panel of the Macro object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Macro object in the digital video surveillance system

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Macro objects in the digital video surveillance system with distributed architecture

2

Name*

Enter the value into the field

Sets the Macro object name.

Latin, Cyrillic and service characters

Macro

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of characters—from 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Macro object 

Boolean type

Clear

Setthe Macro object is disabled and isn't used

Clearthe Macro object is enabled and used

The Settings group

4

State

Enter the value into the field

Sets the message displayed in the information board of the main menu of Axxon PSIM, when the given macro is running

Latin, Cyrillic and service characters

Not defined

Standardno message will be displayed in the information board of the main menu of Axxon PSIM.

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of charactersfrom 1 to 60

5

Local

Set the checkbox

Sets the computers, which will execute the given macro (all computers of the digital video surveillance system with distributed architecture or only the given computer).

Note. This checkbox does not apply to hide and show reactions of any Display. Regardless of the checkbox, when called from the Server/RAW, the reactions are executed on the Server/RAW and all connected Clients; when called on the Client, the reactions are executed only on the Client

Boolean type

Clear

Set—the macro will be executed only on the given computer

Clear—the given macro will be executed on all computers of the digital video surveillance system with distributed architecture

6

Hidden

Set the checkbox

Determines, whether or not the name of this macro will be displayed in the main control panel of Axxon PSIM to be started manually

Boolean type

Clear

Set— the name of the macro will not be displayed in the main control panel of Axxon PSIM

Clearthe name of the macro will be displayed in the main control panel of Axxon PSIM

The Events subgroup

7

Type

Select the value from the list

Sets the type of objects in the digital video surveillance system with distributed architecture, in which the event registration triggers a macro

Types of objects registered in the system

-

Depends on the total number of the types of objects created in the digital video surveillance system with distributed architecture

8

Number

Select the value from the list

Sets the identification number of the object in the digital video surveillance system with distributed architecture, in which the event registration triggers a macro

Sequence of numbers

-

Depends on the total number of the objects of the specified type created in the digital video surveillance system with distributed architecture

9

Name

Automatically

Displays the name of the selected object in the digital video surveillance system with distributed architecture

Names of the objects of the specified type registered in the system

-

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of charactersfrom 1 to 60

10

Event

Select the value from the list

Sets the event that triggers a macro for the specified object

Names of the events available for the given type of objects

-

List of events is created individually for each type of object

The Parameters subgroup

Note. The given subgroup is not active for all types of objects

11

Name

Automatically

Sets the name of the additional parameter for the selected type of object in the Events subgroup

Latin and service characters, digits

Not defined

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters—from 1 to 60

12

Value

Enter the value into the field

Sets the value for the parameter in the Name column

Latin and service characters, digits

Empty field

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of charactersfrom 1 to 250

The Action subgroup

13

Type

Select the value from the list

Sets the type of objects in the digital video surveillance system with distributed architecture, to which the command is forwarded, when the conditions set in the Events subgroup to trigger a macro are met

Names of the types of objects registered in the system

-

Depends on the total number of the types of objects created in the digital video surveillance system with distributed architecture

14

Number

Select the value from the list

Sets the identification number of the object in the digital video surveillance system with distributed architecture, to which the command is forwarded, when the conditions set in the Events subgroup to trigger a macro are met

Sequence of numbers

-

Depends on the total number of the objects of the specified type in the digital video surveillance system with distributed architecture.

If the field is left blank, the reaction will be performed for all objects of the selected type.

If you enter the # symbol in the field, the identifier of the object from which the event was received will be substituted into the reaction. The object types in the Events and Actions tables may differ. When the macro is run manually from the main control panel, the # symbol is treated as if the field was blank, i.e. the macro is executed for all objects of the selected type.
Example of using the # symbol: disarm the camera if the “Detach” event was received from it

15

Name

Automatically

Displays the name of the selected object in the digital video surveillance system with distributed architecture

Names of the objects of the selected type registered in the system

-

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of charactersfrom 1 to 60

16

Action

Select the value from the list

Sets the action, which the given device performs, when the conditions to trigger the given macro are met

Names of the actions, available in the system for the objects of the specified type

-

List of events is created individually for each type of object

The Parameters subgroup

Note. The given subgroup is not active for all types of objects

17

Name

Automatically

Sets the name of the additional parameter for the selected type of object in the Actions subgroup

Latin and service characters, digits

Not defined

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters—from 1 to 60

18

Value

Enter the value into the field

Sets the value for the parameter in the Name column

Latin and service characters, digits

-

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of charactersfrom 1 to 250

Outside the groups

19

Response sending delay (s)

Enter the value into the field

Sets the time period (in seconds) that must pass after the events specified in the Events column occur and before executing the reactions specified in the Actions column.


Note. If the events reoccur before the specified time period expires, the reaction execution wait period will be prolonged, i.e. reactions will be executed only once when events do not reoccur over the specified period

Sequence of numbers

-

>0

20Fast call

Left-click in the field and press the required key combination

Sets a keyboard shortcut for a macro.

Note. If the same combination of keys is set for several macros, when pressing a key combination, all of these macros will run

Key combinations-Individual keys of the main or numeric keyboard, as well as these keys in combination with Shift, Ctrl and Alt
21Icon typeSelect the value from the list

Sets a set of icons for displaying a macro on the map. By default, an empty value is set for all macros which corresponds to the "Macro 1" icon.

Note. Changing the icon type will take effect after restarting the map interface. To restart the interface, restart Axxon PSIM or log in once again under the corresponding Operator account

Available icon types on the map

-Macro 1Macro 7, empty value

*Name of the element isn't displayed in the settings panel of the given object.

  • No labels