Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Manager of failover services object  The Settings panel of the ONVIF-Server Profile object Next page


The ONVIF-Server object is used to transmit Axxon PSIM video signal via the ONVIF protocol.

The settings panel of the ONVIF-Server object is shown in the figure.

The Basic settings tab.

The Event settings tab.

The table describes the setting parameters of the ONVIF-Server object.

ParameterMethod for setting the parameter valueParameter description RepresentationDefault valueValue range
1Identification numberAutomaticallyDisplays the identification number of the ONVIF-Server object in the digital video surveillance system with distributed architectureNumbers, letters, periods, hyphen, dash and underscore-Depends on the number of the ONVIF-Server objects in the digital video surveillance system with distributed architecture
2NameEnter the value into the fieldSets the name of the ONVIF-Server object in the digital video surveillance system with distributed architectureLatin, Cyrillic and service charactersONVIF-Server

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3DisableSet the checkboxSets the state (enabled or disabled) of the ONVIF-Server object in the digital video surveillance system with distributed architectureBoolean typeClear

Setthe ONVIF-Server object is disabled and not in use.

Clearthe ONVIF-Server object is enabled and in use.

4ComputerSelect the value from the list

Sets the Computer parent object in the digital system with distributed architecture to which the given ONVIF-Server object belongs

Names of the Computer objects registered in the systemName of the Computer parent objectDepends on the number of the computers in the digital video surveillance system with distributed architecture
The Basic settings tab
5PortSpecify the value in the fieldSets the port number used to connect to the ServerInteger greater than 0-1–65535
6IP-interface Select the value from the listSets the network interface (network adapter) used to connect to the ServerList of available network interfaces-The list of values depends on the network adapters available in the system
7RTSP-server Select the value from the listSets the RTSP-server object the settings of which will be applied by the ONVIF-Server object while transmitting the video signal Names of the RTSP-server objects registered in the system-

Depends on the number of the RTSP-server objects created in Axxon PSIM

8Use Media2 service
Set the checkboxEnables the ONVIF 2.X standard instead of ONVIF 1.XBoolean typeClear

Set—the ONVIF 2.X standard is used. The video is transmitted in the H264, H265, MJPEG or MPEG4 formats

Clear—the ONVIF 1.X standard is used. The video is transmitted in the MPEG, MJPEG or H264 formats

9Allow DHCP setting
Set the checkboxEnables the DHCP supportBoolean typeClear

SetDHCP is used

ClearDHCP isn't used

10Discovery modeSet the checkboxEnables the WS-Discovery modeBoolean typeSet

Set—the WS-Discovery mode is enabled

Clear—the WS-Discovery mode is disabled

11BrandEnter the value into the fieldSets the name of the brand that will be displayed in the third-party clients that support the video transmission via the ONVIF protocolLatin, Cyrillic and service charactersAxxonSoft Ltd.

A line containing a sequence of any characters (letters, digits and service characters)

12ModelEnter the value into the fieldSets the name of the model that will be displayed in the third-party clients that support the video transmission via the ONVIF protocolLatin, Cyrillic and service charactersPSIMA line containing a sequence of any characters (letters, digits and service characters)
13DepartmentSelect the value from the listSets the department in which the users will be created when they are added via the ONVIF-Server interfaceNames of the Department objects registered in the system-

Depends on the number of the departments registered in Axxon PSIM

14Use RTSP over HTTP ProxySet the checkboxRedirects all RTSP-Server and ONVIF-Server requests to the specified port for the operation behind NATBoolean typeClear

Setthe RTSP-Server and ONVIF-Server requests are redirected to the specified port

Clearthe RTSP-Server and ONVIF-Server requests are transmitted to the port specified in the Connection settings group (see item 5 above)

15PortEnter the value into the fieldSets the port number for the RTSP-Server and ONVIF-Server requests redirection for the operation behind NATInteger greater than 0-1–65535
16NAT IP addressEnter the value into the fieldSets the IP address that the ONVIF Server will use in responses to Clients if the Clients are behind NATIP address-Depends on the network settings behind NAT
The Event settings tab
17ONVIF-server eventSelect the value from the listSets the ONVIF-server event according to the ONVIF specificationList of available events-According to the ONVIF specification
18ComputerSelect the value from the list

Sets the Computer object on the basis of which the object is created that is the event source in Axxon PSIM

Names of the Computer objects registered in the system-Depends on the number of the computers in the digital video surveillance system with distributed architecture
19TypeSelect the value from the listSets the event type which is the event source in Axxon PSIMNames of the object types registered in the system-Depends on the number of the created objects in the digital video surveillance system with distributed architecture
20NumberSelect the value from the listSets the object number which is the event source in Axxon PSIMSequence of numbers-Depends on the number of the created objects in the digital video surveillance system with distributed architecture
21NameAutomaticallySets the object name which is the event source in Axxon PSIMNames of the object of the selected type registered in the system-Depends on the number of the created objects in the digital video surveillance system with distributed architecture
22EventSelect the value from the listSets the event name in Axxon PSIMEvent names received from the objects of the selected type-Depends on the object type
23ONVIF-event parameter nameAutomaticallySets the ONVIF-event parameter name according to the specificationParameter names of the selected ONVIF-event-According to the ONVIF specification
24Event parameter nameEnter the value into the fieldSets the event parameter name in Axxon PSIMEvent parameter names in Axxon PSIM-Depends on the object type
  • No labels