Go to documentation repository
The Program object is used to create specialized programs in the embedded programming environment of Axxon PSIM.
The settings panel of the Program object is shown in the figure.
Table describes the setting parameters corresponding to the elements of the settings panel of the Program object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number | Automatically | Displays the identification number of the Program object in the video surveillance system | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Program objects in the digital video surveillance system with distributed architecture |
2 | Name | Enter the value into the field | Sets the name of the Program object | Latin, Cyrillic and service characters | Program | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (enabled or disabled) of the Program object | Boolean type | Clear | Set—the Program object is disabled and isn't used Clear—the Program object is enabled and used |
4 | Time schedule | Select the value from the list | Sets the time period during which the given program operates | Names of the Time schedule registered in the system | Never | Never—this program will never be executed Always—this program is always in the state of execution List of the created time schedules—the program will be executed within a pre-defined time period |
The Computers group | ||||||
5 | Select an element | Set the checkbox | Sets the computer on which the given program will be executed | Boolean type | Clear | Set—the program will be executed on the specified computer Clear—the program will not be executed on the computer |
6 | Computer | Automatically | Sets the name of the computer in the local network | Computer name in the local network | Computer name in the local network | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
7 | Name | Automatically | Sets the name of the computer | Name of the Computer object registered in the system | Name of the Computer object registered in the system | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
Not in a group | ||||||
8 | Filter | Enter the value into the field | Used to pre-filter events processed by the program | Latin, Cyrillic, service characters, and digits | Not defined | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited. Filter format is TYPE|ID|EVENT divided by semicolon. For example, CAM||MD_STOP;CAM||MD_START to filter Alarm and Alarm end events from all Camera objects |
9 | Text editor | Enter the value into the field | Used to enter the text of the program that must be executed | Latin, Cyrillic and service characters, digits | Not defined | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited |