Go to documentation repository
The settings panel of the SIP-panel object is shown in the figures below.
Table describes the setting parameters of the SIP-panel interface object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Position group | ||||||
1 | X | Enter the value into the field | Sets the X coordinate in the horizontal axis for the upper left corner of the SIP-panel interface window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
Y | Enter the value into the field | Sets the Y coordinate in the vertical axis for the upper left corner of the SIP-panel interface window | % of the screen height | - | From 0 to M*100, where M is the number of the installed monitors | |
2 | W | Enter the value into the field | Sets the width of the SIP-panel interface window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
H | Enter the value into the field | Sets the height of the SIP-panel interface window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors | |
3 | The × button | Click the button | Opens a test window for changing the coordinates of the SIP-panel interface window | - | - | - |
4 | Monitor | Select the value from the list | Sets the number of the monitor in the system for which the coordinates are specified | Numbers of the monitors in OS | 1 | From 1 to 16 |
The Basic settings tab.
Table describes the parameters of the Basic settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Terminal | Select the value from the list | Sets the SIP-terminal object, which SIP-devices use the SIP-panel | Name of the SIP-panel objects registered in the system | - | Depends on the number of the SIP-terminal objects in the system |
2 | Monitor | Select the value from the list | Sets the the Monitor object corresponding to the Video surveillance monitor to which the video cameras associated with the corresponding SIP-devices are added | Name of the Monitor objects registered in the system | - | Depends on the number of the Monitor objects in the system |
The Advanced settings tab.
Table describes the parameters of the Advanced settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Interface behavior group | ||||||
1 | Display only when calling | Set the checkbox | Displays the SIP-panel only when calling | Boolean type | Clear | Set—the SIP-panel is only displayed when calling Clear—the SIP-panel is always displayed |
2 | New calls to the end | Set the checkbox | Enables adding new calls to the end of the list | Boolean type | Clear | Set—new calls are added to the end of the list Clear—new calls are added to the top of the list |
3 | Disable keypress sound | Set the checkbox | Disables keypress sound on the SIP-panel | Boolean type | Clear | Set—keypress sound disabled Clear—keypress sound is enabled |
4 | Maximize screen on call | Set the checkbox | Enables automatic display switching on call | Boolean type | Clear | Set—when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically Clear—when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen is not displayed automatically |
5 | Calls to unknown users | Set the checkbox | Enables the option to call unknown users Note. Unknown user is a number that is present in the SIP-terminal, but not in the address book of the current SIP-operator | Boolean type | Set | Set—calls to unknown users are allowed Clear—calls to unknown users are not allowed |
6 | Switch to incoming | Set the checkbox | Automatically switches to the tab of the SIP-panel with the incoming calls, which occurs with incoming calls or call on hold | Boolean type | Set | Set—automatic switch to the tab with incoming calls is enabled Clear—automatic switch to the tab with incoming calls is disabled |
The Interface elements group | ||||||
7 | Dial pad | Set the checkbox | Displays the dial pad in the interface | Boolean type | Set | Set—the dial pad is displayed Clear—the dial pad is hidden |
Caption | Set the checkbox | Displays the tab names in the interface. When disabled, only the Call tab will be displayed without displaying the name | Boolean type | Set | Set—the tab names are displayed Clear—only the Call tab is displayed without displaying the name | |
Archive | Set the checkbox | Displays the Archive tab in the interface | Boolean type | Set | Set—the Archive tab is displayed Clear—the Archive tab is hidden | |
Call control buttons | Set the checkbox | Displays the buttons at the bottom of the panel to control a call | Boolean type | Set | Set—call control buttons are displayed Clear—call control buttons are hidden |
The Operator settings tab.
Table describes the parameters of the Operator settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Operators table | Select the value in the column | Sets the list of the SIP-operators who can work with this SIP-panel | - | - | - |
Number | Select the value from the list | Selects a SIP-operator identifier | Identifiers of the SIP-operator objects registered in the system | - | Depends on the number of the SIP-operator objects in the system | |
Subscriber | Select the value from the list | Selects a SIP-operator number | Numbers of the SIP-operator objects registered in the system | - | Depends on the number of the SIP-operator objects in the system | |
Name | Select the value from the list | Selects a SIP-operator name in Axxon PSIM | Names of the SIP-operator objects registered in the system | - | Depends on the number of the SIP-operator objects in the system | |
2 | All | Click the button | Adds all existing SIP-operators to the table | - | - | - |
3 | Range | Click the button | Opens the Add operators window to add multiple SIP-operators | - | - | - |
4 | Default | Select the value from the list | Sets the default SIP-operator | - | Select on start | Select on start—when you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time you will be logged in under the previously selected SIP-operator User rights—you will log into the SIP-panel as the SIP-operator that is linked to the Axxon PSIM user rights. You should also be logged into Axxon PSIM with the corresponding user rights SIP-operator from the list—logging into the SIP-panel will be made at once as the selected SIP-operator. Depends on the number of the SIP-operator objects in the system |