Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Charts object  The Settings panel of the Incident manager object Next page


The settings panel of the SIP-panel object is shown in the figures below.

Table describes the setting parameters of the SIP-panel interface object.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Position group

1


X

Enter the value into the field

Sets the X coordinate in the horizontal axis for the upper left corner of the SIP-panel interface window

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors

Y

Enter the value into the field

Sets the Y coordinate in the vertical axis for the upper left corner of the SIP-panel interface window

% of the screen height

-

From 0 to M*100, where M is the number of the installed monitors

2



W

Enter the value into the field

Sets the width of the SIP-panel interface window

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors

H

Enter the value into the field

Sets the height of the SIP-panel interface window 

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors

3The × buttonClick the button

Opens a test window for changing the coordinates of the SIP-panel interface window

---
4MonitorSelect the value from the list

Sets the number of the monitor in the system for which the coordinates are specified

Numbers of the monitors in OS1From 1 to 16

The Basic settings tab.

Table describes the parameters of the Basic settings tab.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1TerminalSelect the value from the listSets the SIP-terminal object, which SIP-devices use the SIP-panelName of the SIP-panel objects registered in the system-Depends on the number of the SIP-terminal objects in the system
2MonitorSelect the value from the listSets the the Monitor object corresponding to the Video surveillance monitor to which the video cameras associated with the corresponding SIP-devices are addedName of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system

The Advanced settings tab.

Table describes the parameters of the Advanced settings tab.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Interface behavior group

1

Display only when calling

Set the checkbox

Displays the SIP-panel only when calling

Boolean type

Clear

Setthe SIP-panel is only displayed when calling

Clearthe SIP-panel is always displayed

2New calls to the endSet the checkboxEnables adding new calls to the end of the listBoolean typeClear

Setnew calls are added to the end of the list

Clearnew calls are added to the top of the list

3Disable keypress soundSet the checkboxDisables keypress sound on the SIP-panelBoolean typeClear

Setkeypress sound disabled

Clearkeypress sound is enabled

4Maximize screen on callSet the checkboxEnables automatic display switching on callBoolean typeClearSetwhen a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically

Clearwhen a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen is not displayed automatically

5Calls to unknown usersSet the checkbox

Enables the option to call unknown users

Note. Unknown user is a number that is present in the SIP-terminal, but not in the address book of the current SIP-operator

Boolean typeSet

Setcalls to unknown users are allowed

Clearcalls to unknown users are not allowed

6Switch to incomingSet the checkboxAutomatically switches to the tab of the SIP-panel with the incoming calls, which occurs with incoming calls or call on holdBoolean typeSet

Set—automatic switch to the tab with incoming calls is enabled

Clear—automatic switch to the tab with incoming calls is disabled

The Interface elements group
7Dial padSet the checkboxDisplays the dial pad in the interfaceBoolean typeSet

Setthe dial pad is displayed

Clearthe dial pad is hidden

CaptionSet the checkboxDisplays the tab names in the interface. When disabled, only the Call tab will be displayed without displaying the nameBoolean typeSet

Setthe tab names are displayed

Clearonly the Call tab is displayed without displaying the name

ArchiveSet the checkboxDisplays the Archive tab in the interfaceBoolean typeSet

Setthe Archive tab is displayed

Clearthe Archive tab is hidden

Call control buttons Set the checkboxDisplays the buttons at the bottom of the panel to control a callBoolean typeSet

Setcall control buttons are displayed

Clearcall control buttons are hidden

The Operator settings tab.

Table describes the parameters of the Operator settings tab.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range

1

The Operators tableSelect the value in the columnSets the list of the SIP-operators who can work with this SIP-panel---
NumberSelect the value from the listSelects a SIP-operator identifierIdentifiers of the SIP-operator objects registered in the system-Depends on the number of the SIP-operator objects in the system
SubscriberSelect the value from the listSelects a SIP-operator numberNumbers of the SIP-operator objects registered in the system-Depends on the number of the SIP-operator objects in the system
NameSelect the value from the listSelects a SIP-operator name in Axxon PSIMNames of the SIP-operator objects registered in the system-Depends on the number of the SIP-operator objects in the system
2AllClick the buttonAdds all existing SIP-operators to the table---
3RangeClick the buttonOpens the Add operators window to add multiple SIP-operators---
4DefaultSelect the value from the listSets the default SIP-operator-Select on start

Select on startwhen you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time you will be logged in under the previously selected SIP-operator

User rightsyou will log into the SIP-panel as the SIP-operator that is linked to the Axxon PSIM user rights. You should also be logged into Axxon PSIM with the corresponding user rights

SIP-operator from the listlogging into the SIP-panel will be made at once as the selected SIP-operator. Depends on the number of the SIP-operator objects in the system

  • No labels