Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Time schedule object  The Settings panel of the Region object Next page


The Script object is used to create specialized programs in the JScript language.

The settings panel of the Script object is shown in the figure.

 

Table describes the setting parameters corresponding to the elements of the settings panel of the Script object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Script object in the digital video surveillance system

Sequence of numbers

-

Depends on the number of the Script objects in the digital video surveillance system with distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Script object

Latin, Cyrillic and service characters

Script

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of characters—from 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Script object in the digital video surveillance system with distributed architecture

Boolean type

Clear

Setthe Script object is disabled and isn't used

Clearthe Script object is enabled and used

4

Time schedule

Select the value from the list

Sets the time period during which the given script operates

Names of the Time schedule registered in the system

Never

Neverthe script will never be executed

Always—this script is always in the state of execution

List of the created time zonesthe script will be executed within a pre-defined time period

The Run on specified computers group

5

Select an element*

Set the checkbox

Sets the computer on which the given script will be executed

Boolean type

Clear

Setthe script will be executed on the specified computer

Clearthe script will not be executed on the computer

6

Computer

Automatically

The name of the computer in the local network

Computer name in the local network.

Computer name in the local network.

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters—from 1 to 60

7

Name

Automatically

Sets the name of the computer in the digital video surveillance system with distributed architecture

Name of the Computer object registered in the system

Name of the Computer object registered in the system

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters—from 1 to 60

Outside the group

8

Text editor*

Enter the value into the field

Used to enter the text of the script that should be executed

Latin, Cyrillic and service characters

Not defined

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Unlimited number of characters

9

Editor - Debugger

Click the button

Open a debugging window of the script

-

-

-

10

Object type

Select the value from the list

Sets the type of the object, on receiving an event from which the script will be executed

Types of the objects registered in the system

-

Depends on the number of the objects registered in the system

11

ID

Select the value from the list

Sets the identifier of the object, on receiving an event from which the script will be executed

Identifiers of the objects of the selected type registered in the system

-

Depends on the number of the objects of the selected type registered in the system

12

Object name

Automatically

The name of the object, on receiving an event from which the script will be executed

Name of the object of the selected type with the selected identifier

-

Depends on the specified object identifier

13

Event

Enter the value into the field

Sets the event, on receiving which from the object of the selected type the script will be executed

Events supported by the object

-

Depends on the events supported by the object. The name of the event should be entered in upper case

*Name of the element isn't displayed in the settings panel of the given object.

  • No labels