Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the Keyboard object  The Settings panel of the Voice notification service object Next page


The settings panel of the System restart service object is shown in the figure.

Table describes the setting parameters of the System restart service object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number

Automatically

Displays the identification number of the System restart service object in the system


Sequence of numbers

-

From 1 and above.

Depends on the number of the System restart service objects in the system



2

Name

Enter the value into the field

Sets the name of the System restart service object in the system



Latin, Cyrillic and service characters

System restart service

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the System restart service object in the system


Boolean type

Clear

Setthe System restart service object is disabled and isn't used

Clearthe System restart service object is enabled and used

4

Computer

Select the value from the list

Sets the Computer parent object in the system, to which the given System restart service object belongs


Name of the Computer objects registered in the system

Name of the Computer parent object

Name of the Computer parent object (the System restart service object cannot be edited remotely)

5

AxxonSoft USB Watchdog for PSIM_Host.exe

Set the checkbox

Activates the system of the computer automatic restart when the psim_host.exe process isn't active

Boolean type

Clear

Setthe system of automatic restart is activated

Clearthe system of automatic restart is deactivated


Table of the performance monitoring of Axxon PSIM modules

6

Module

Automatically

Displays the list of the modules running on the computer

Names of the running modules

-

Depends on the number of the modules registered in the system

7

Status, hours

Automatically

Displays the current state of the modules

Names of the current states of the modules

-

loaded—module runs

unloaded (red field)no response from the module after the waiting time expires

unloaded (no coloring)module is unloaded

Note. The time of the module run time since the last restart is displayed in the HH:MM:SS format in the square brackets

8

Response time, s

Enter the value into the field

Sets the time interval in seconds of the module response time. If there is no response after the specified time, the system can be restarted

Non-negative integers

60

From 0 and above

9

Quantity of restarts

Enter the value into the field

Sets the maximal quantity of restarts for a period of time, specified in the In time and Type of period columns

Non-negative integers

3

From 0 and above

10

In time

Enter the value into the field

Set period of time during which the maximum quantity of the system restarts can be performed

Non-negative integers

1

From 0 and above

11

Type of period

Select the value from the list

Names of time period units

hours

hoursthe time period is measured in hours

daysthe time period is measured in days

12

Restart

Select the value from the list

Sets the type of the system restart

Names of the possible types of restart

none

nonerestart isn't performed

modulemodule restart is performed

coreAxxon PSIM core restart is performed

13

Remains of restarts

Automatically

Displays the quantity of the remaining restarts for the period specified in the In time and Type of period columns

Non-negative integers

-

Depends on the maximum quantity of restarts and on the number of restarts that were performed for a current time period

14

Memory (Mb)

Enter the value into the field

Sets the module memory consumption threshold above which the module should be restarted

Non-negative integers

0

From 0 and above