Go to documentation repository
The Telemetry Controller object is used to register and configure in Axxon PSIM the serial (COM) ports used for connecting the PTZ devices.
The settings panel of the Telemetry Controller object is shown in the figure.
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Telemetry Controller object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Telemetry Controller object in the digital video surveillance system with the distributed architecture | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Telemetry Controller objects in the igital video surveillance system with the distributed architecture |
2 | Name* | Enter the value into the field | Sets the name of the Telemetry Controller object in the digital video surveillance system with the distributed architecture | Latin, Cyrillic characters and service characters | Telemetry Controller No. | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state of the Telemetry Controller object (enabled or disabled) in the digital video surveillance system with the distributed architecture | Boolean type | Clear | Set—the Telemetry Controller object is disabled and isn't used Clear—the Telemetry Controller object is enabled and is used |
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture, to which the given Telemetry Controller object belongs | Name of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the digital system with the distributed architecture |
The Settings group | ||||||
5 | Controller type* | Select the value from the list | Sets the data communication protocol with the PTZ device via the serial (COM) port. Data communication protocols are supplied by the PTZ devices manufacturers | Name of the PTZ devices integrated in the system | Videotec | Corresponds to the list of the PTZ devices integrated in the system |
6 | Port | Select the value from the list | Sets the number of the computer COM port, used to connect the PTZ devices | List of the available COM ports | COM1 | Depends on the number of COM ports on the Server or Remote Administrator’s workstation. If a non-null value is selected, then the local COM port has a higher priority than other devices when processing the PTZ device commands. Otherwise, the COM port priority is set by default |
7 | Rate | Select the value from the list | Sets the data communication rate via the COM port | kB/s | 9600 | From 300 to 256000 |
8 | Parity | Select the value from the list | Sets the parity check mode for the data transfer via the COM port | List of parity check names and modes | None | Even, Odd, None, Mark, Space |
9 | DTR | Set the checkbox | Sets the power supply to the PTZ device via the output of the DTR COM port | Boolean type | Set | Set—the power will be supplied via the DTR port output Clear—the power will not be supplied via the DTR port output |
10 | RTS | Set the checkbox | Sets the power supply to the PTZ device via the output of the RTS COM port | Boolean type | Set | Set—the power will be supplied via the RTS port output Clear—the power will not be supplied via the RTS port output |
*Name of the element is not displayed in the settings panel of the given object.