Configure the Suprema BioMini control reader as follows:
Connect the reader to a Server, download and install driver from the manufacturer's official web site.
Note
Registration on this site is required for download.- Create the Suprema BioMini object based on the Computer object on the Hardware tab of the System Settings dialog box.
In the Security Level drop-down list (1) select the fingerprint verification quality level:
Lowest (1/1000) — the lowest level.
Low (1/10 000) — low level.
Normal (1/100 000) — average level.
High - (1/1 000 000) — high level.
Highest (1/10 000 000) — the highest level.
- Click Apply (2) to save the settings.
Note
- Capturing fingerprints with this control reader in the Access Manager is described in the Capturing fingerprints of Access Manager users with Suprema BioMini.
- The Suprema RealScan control reader is to be used only with the Suprema 2 integration module — see Guide for configuring and working with the Suprema 2 integration module.
Attention!
The module requires the 32-bit version of the Microsoft Visual C++ 2008 redistributable package to be installed. If this component is not installed in your system, use the redist/en/x86/vc90redist.exe installer provided in the ACFA PSIM installation package.
Configuring Suprema BioMini control reader is completed.