Go to documentation repository
Documentation for ACFA PSIM 1.3.
The AIM SC reader is configured on the settings panel of the Apollo AIM SC Reader object. This object is created on the basis of the Apollo AIM SC object.
To configure the AIM SC reader, do the following:
- From the Number drop-down list (1), select the reader's address.
- Set the Activate checkbox (2) to activate the AIM SC reader.
- In the Modes group (3), configure the reader operation modes:
From the Initial drop-down list select the mode of reader operation when establishing the connection.
Operation mode Description Closed Access is closed for all Only card Access granted by access card PIN or card Access granted by access card or PIN code Card and PIN Access granted by access card and PIN code Opened Access is opened for all Facility code Access is granted by facility code - From the Independent drop-down, list select the mode of reader operation when the connection is lost.
- Set the Use initial mode checkbox if it's required to switch to initial mode after writing the configuration.
In the Time group (4), set the time parameters of the reader:
Parameter Parameter setting method Description Time of door closing, s Enter the value in the field Time of opening in seconds Time of door holding, s Enter the value in the field Time period in seconds during which door is to be closed. Otherwise, the Door holding message will be triggered Alternative time of door closing, s Enter the value in the field Alternative time of opening in seconds. It is in use by special command (from card, using macro or script) Alternative time of door holding, s Enter the value in the field Alternative time period in seconds during which door is to be closed. Otherwise, the Door holding message will be triggered. It is in use by special command (from card, using macro or script) In the Advanced settings group (5), set the additional reader parameters:
Parameter Parameter setting method Description Make decision on access locally Set the checkbox Set—the AIM module makes an access decision without the AAN central controller Warning before alarm Set the checkbox Set—trigger warning before alarm Entrance by two cards Set the checkbox Set—passage through the reader is performed by two cards Sound notification while door unblocking Set the checkbox Set—sound signal of reader while unblocking the door Disable second door in binding mode Set the checkbox Set—block the reader working for exit from secured areas Disable only bounded reader while blocking Set the checkbox Set—only bounded reader are blocked while locking signal
Clear—all readers are blocked
Use "soft" APB Set the checkbox Set—antipassback is available, but the corresponding mistake will be specified in message Use cards buffering while passage Set the checkbox Set—write access cards to the AIM while passing Mode of additional relay Select the value from the list Disabled—mode of additional relay is disabled
Enabled—mode of additional relay is enabled
In the Basic settings group (6), set the basic parameters of the reader:
Parameter Parameter setting method Description Allow impulse reset Set the checkbox Set—impulse reset enabled Do not use full time of door closing Set the checkbox Set—lock after door closing Do not use exit button Set the checkbox Set—disable exit button Use AUX as sensor of door opening Set the checkbox Set—use additional AUX sensor of the AIM module as sensor for door opening Do not wait for access cycle Set the checkbox Set—access is performed after making an access decision
Clear—access is performed after triggering a sensor of door opening
- In the Regions group (7):
- From the Entrance to drop-down list, select the Region object corresponding to the area on the side of exit through this reader.
From the Exit from drop-down list, select the Region object corresponding to the area on the side of entrance through this reader.
Note
In order to be able to select partitions, it is necessary to bind these partitions in the Matching of regions group on the settings panel of the Apollo AIM SC object (see Configuring the AIM SC controller).
- Click the Apply (8) button.