Documentation for ACFA PSIM 1.3.

Previous page Advanced settings of a Hikvision controller/terminal  Configuring the Hikvision reader Next page

Note

The Hikvision door configuration options depend on the Hikvision controller/terminal model. The Hikvision door configuration will be illustrated by an example of the Hikvision DS-K26x series controller.

To configure the Hikvision door, do the following:

  1. Go to the settings panel of the Hikvision 26X Door object that is created on the basis of the Hikvision 26X object.
  2. From the Number drop-down list, select the number corresponding to the door number in the Hikvision controller.
  3. In the Door name field, enter the name of the door that will be displayed in ACFA PSIM during further readings of the Hikvision controller configuration.
  4. From the Door magnetic drop-down list, select which door state is a normal state: closedNormal Closed (default) or openNormal Opened.
  5. From the Exit button type drop-down list, select the exit button type: normally closedNormal Closed (default) or normally openNormal Opened.
  6. In the Unlock time field, enter the time in seconds after which the unlocked door will be locked again.
  7. In the Unlock time for disabled pass field, enter the time during which the door will be opened for users who have the Disabled card type.
  8. In the Unlock timeout Alarm field, enter the time in seconds after which an alarm will be initiated if the door wasn't closed.
  9. In the Duress code field, enter the duress code for opening the door by an employee under duress. The duress alarm will be initiated. The duress code must consist of four to eight digits.
  10. In the Super password field, enter the super password that can be used to open this door. The super password must consist of four to eight digits.

    Note

    Duress code and Super password must be different from each other and from the authentication password.

  11. In the Dismiss code field, enter the dismiss code that can be used to disable the card readers of this door. The dismiss code must consists of four to eight digits.
  12. Set the Locking Door when it Closed checkbox if you want to lock the door immediately after closing it. If the checkbox is clear, the door will be locked after the Unlock time time expires (see step 6). By default, the checkbox is clear.
  13. Set the Enable first card remain open checkbox if you want to use the first card model. By default, the checkbox is clear.

    Note

    You can set several first cards for one door. The door will be available for other users with any authorization type only after the first card is swiped.

  14. From the First card model drop-down list, select the first card model: Disabled, Normal Open or Authorization.

    1. Disabled—disables the first card model.

    2. Normal Open—when the first card is swiped, the door remains open for the time specified in the Remain open duration, min field (see step 15).

    3. Authorizationany kind of authentication (except for super card, super password and duress card/code authentication) is accepted only after the first card is authorized.

      Note

      The first card authorization is valid for the current day only. The authorization expires in 24 hours on the current day. Re-swipe the same first card to disable the first card model.

  15. In the Remain open duration, min field, enter the time in minutes during which the door remains open after the first card is swiped with the Normal Open model. The default value is 10 minutes.
  16. In the Multiauthentication swipe time field, enter the maximum time between card reading/password entry and other authentication methods when using a multiple card configuration (see Configuring multiple Hikvision cards).
  17. Click the Apply button to save the settings.