Go to documentation repository
Documentation for ACFA PSIM 1.3.
When the HID integration module's object tree is created semiautomatically, controllers are created manually, but interface modules, readers, and actuators are created automatically.
To create the object tree semiautomatically:
- Create the required number of controller objects (VertX V1000 Network Controller, VertX V2000 NC / RI, and E400 EdgeReader Interface objects), one for each connected device: go to the Settings dialog box, click the Hardware tab, and select the parent VertX / Edge ACS object.
- For each created object, go to its setup panel and enter the MAC address of the corresponding connected device (controller).
- Go to the VertX / Edge ACS object's setup panel.
- Click Get configuration from...
The controller selection window opens . Select the checkboxes of the controllers whose configuration (interface modules, readers, and actuators) you want to get (1).
Note:
This window shows the created controller objects.- Click Apply (2).
The object tree is then created.
Note:
During the object tree creation process, you will see messages in the Event log interface window.
Attention!
When the object tree is created semiautomatically, an object is created for each connected device. Do not manually add objects to the created tree.
Overview