Recognition settings of the Hikvision reader are available for access control terminals that have both a face scanner and a built-in fingerprint reader.
Note
Recognition settings of the Hikvision reader will be illustrated by an example of the Hikvision DS-K1T605MF access control terminal. You can configure the recognition settings of a reader of other Hikvision terminals in the similar way.
To configure the recognition settings of the Hikvision reader, do the following:
- Go to the settings panel of the Hikvision K1T605XF Reader object.
- Go to the Recognition tab.
- From the Recognition level drop-down list, select the recognition level:
- 1/1000(FAR).
- 1/100000(FAR).
- 1/1000000(FAR).
- 3/100000(FAR).
3/1000000(FAR).
Note
The higher the recognition level, the lower the probability of false identification.
- Set the Enable Card No. Reversing checkbox to enable the ability to read the information from the protected area of the card. By default, the checkbox is clear.
- From the Recognition Interval drop-down list, select the time interval in seconds between the previous and next face recognition during the continuous operation in the range from 1 to 10. The default value is 2s.
- From the Recognition timeout drop-down list, select the time in seconds in the range from 1 to 20, after which the connection with the Axxon PSIM Server is broken if there is no recognition. The default value is 3s.
- In the Face Grading field, specify the minimum acceptable image quality for face recognition in percent. The default value is 50%.
- From the 1:1 Match Security Level drop-down list, select the verification quality level if only one type of authentication is used: Normal, High, or Higher.
- In the 1:1 Matching Threshold field, specify the maximum allowable variation from the 1:1 Match Security Level value if only one type of authentication is used. The default value is 50%.
- From the 1:N Match Security Level drop-down list, select the verification quality level if several types of authentication are used: Normal, High, or Higher.
- In the 1:N Matching Threshold field, specify the maximum allowable variation from the 1:N Match Security Level value if several types of authentication are used. The default value is 50%.
- From the Application Mode drop-down list, select the application mode of the Hikvision reader: Indoor, Invalid, Other.
- From the Human detection drop-down list, select if the detection of live faces is used: Invalid (default), Disable, Enable.
- From the Human detection level drop-down list, select the level of human recognition: Invalid, Low, Middle, High.
- Click the Apply button.