Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.

Previous page Possible errors during installation  Possible errors during operation Next page

The Client cannot be connected to the Server

If a "Cannot find Server" message appears after you connect to a Server, do the following:

  1. Go to Control Panel -> Regional Settings -> More.
  2. Change current language of non-Unicode applications to the one that is present in keyboard settings, and may appear in user name and folders.
  3. Reboot the PC.

If a Connection Error message appears after you connect to a Server, do the following:

  1. Go to Local Security Policy interface.
  2. Select Local Policies -> Security Settings.
  3. Turn off the following parameter: System cryptography: use FIPS compliant algorithms for encryption, hashing, and signing.

Launching the Axxon One software program with client logging enabled can take a long time when the ESET NOD32 Antivirus 4 Real-time file system protection mode is on.

To solve this problem, add the Axxon One installation folder and the folder with the client logs (<Letter of system disk>:\Users\<User>\Appdata\Local\AxxonSoft\Axxon One\logs) to the list of exceptions in ESET NOD32 Antivirus 4.