Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

You can configure the correspondence of messages for Topic Filter and the Intellect Axxon PSIM events. The remaining events and messages are sent automatically according to the specification (for example, when changing the server, profile or MotionAlarm settings, etc.).

The correspondence of messages for Topic Filter and the IntellectAxxon PSIM events is configured in the following order:

  1. Go to the Event settings tab on the settings panel of the ONVIF-Server object.
  2. From the drop-down list of the ONVIF-server event column, select the ONVIF-Server event (1). See the events description in the table at the bottom of the page.

    Info
    titleNote

    To add a row to the table, press the "down" button on the keyboard; to delete a row, use the Ctrl+Del keyboard shortcut.


  3. In the Computer, Type and Number columns specify the parameters of the required object, from which the corresponding event comes (2). The Name field will be filled in automatically when you left-click it. If any column parameter is empty, it means that the message will be sent for any value of the corresponding parameter.
  4. From the Event drop-down list, select an event which comes from the selected object and corresponds to the specified ONVIF-Server message (3).
  5. If the specification requires that the event should contain certain parameters (see the table at the bottom of the page), it is necessary to specify their values or the correspondence to the Intellect Axxon PSIM event parameters in the Transfer parameters table:
    1. The ONVIF-event parameter name column contains the required parameters of the ONVIF-Server event (4). They are set according to the specification.
    2. In the Event parameter name column, it is necessary to specify the parameter value or the Intellect Axxon PSIM event parameter names (5). Event parameters can be found in the Debug window, and some of them are described in the Description of system object reactions section (see Programming Guide).

  6. Repeat steps 2-5 for all required events.
  7. Click the Apply button (6).

...

EventEvent descriptionParametersIs configuration required
tns1:Device/AccessControl/AccidentAccess Control System incident

Name

Comment

Place

Yes
tns1:Device/AccessControl/FaultAccess Control System failure
tns1:Device/FireAlarm/AlarmFire Alarm System alarm

Category

Zone

Comment

Yes
tns1:Device/FireAlarm/FireFire message from Fire Alarm System
tns1:Device/FireAlarm/FaultFire Alarm System failure
tns1:Device/GasAnalysis/ConcentrationExceededIncreased concentration of hazardous gases

Place

ConcentrationLimit

GasType

Concentration

Comment

Yes
tns1:Device/Introscopy/LimitExceeded

Detection of metal objects and organic matter

Account

Picture

Result

Yes
tns1:Device/NeutronProbing/DetectDetection of explosives

Place

ExplosiveType

Location

Comment

Yes
tns1:Device/RadiationMonitoring/Detect

Increased radiation

Picture

Category

Measures

Account

Yes
tns1:Device/SteamDetector/Detect

Detection of vapors and trace amounts of explosives which exceed the established threshold values

Measures

Picture

Account

Yes
tns1:Device/MetalDetector/Detect

Detection of metal objects which exceed the specified values.

Picture

Account

Yes
tns1:Device/VideoSurveillanceSystem/ChannelDisconnectVideo channel disconnection

Category

Comment

Priority

Yes
tns1:Device/VideoSurveillanceSystem/ChannelConnectVideo channel connection
tns1:Device/VideoSurveillanceSystem/RecordTurnOffRecording turned off
tns1:Device/VideoSurveillanceSystem/RecordTurnOnRecording turned on
tns1:Device/VideoSurveillanceSystem/MotionDetectorTriggerMotion detector triggering
tns1:Device/VideoSurveillanceSystem/ReadRecordRequestRequest for the record reading
tns1:Device/VideoSurveillanceSystem/DeleteRecordRequestRequest for the record deletion
tns1:Device/VideoSurveillanceSystem/EditDbRecordRequest

Request for the event database editing

tns1:Device/VideoSurveillanceSystem/CopyDbRecordRequestRequest for the event database copying
tns1:Device/VideoSurveillanceSystem/AuthorizationSystem user authorization
tns1:Device/VideoSurveillanceSystem/ServerPowerOnServer switched on
tns1:Device/VideoSurveillanceSystem/ServerPowerOffServer switched off
axn:HDDrive/axn:FaultHard disk error-No
axn:HDDrive/axn:RecordingFaultHard disk failure-No
axn:HDDrive/axn:DriveFullHard disk full (if overwriting on a loop is not enabled)-No
axn:VideoSurveillanceSystem/axn:ChannelDisconnectVideo camera disconnection-No
axn:VideoSurveillanceSystem/axn:ChannelConnectVideo camera connection-No
axn:VideoSurveillanceSystem/axn:ServerPowerOnAny IntellectAxxon PSIM Servers switching on in a distributed architecture-No
axn:VideoSurveillanceSystem/ServerPowerOffAny IntellectAxxon PSIM Servers switching off in a distributed architecture-No

...