Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Setting the trap with SNMP-message is done in the following way:

  1. Go to the settings panel of SNMP trap system object.
  2. In the IP field, enter IP-address from SNMP-manager, that will receive SNMP-traps with messages concerning the events (1).
  3. In the field Group, enter the community name for SNMP-trap authentication on the computer with installed SNMP-manager(2).

    Info
    titleNote.
     Safety model on the basis of communities is realized in Axxon PSIM program complex.


  4. In the field Variable OID, enter the unique trap’s number in the tree of SNMP-objects (3).
  5. To save the changes click Apply button (4).

Setting up the trap with SNMP-message is completed.