Go to documentation repository
The Display object is designed used to register virtual screens displays in the system, which are used as a basis for interface components created in the Axxon PSIM system. The settings panel of the Display object is shown in the figure.
The table Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Display object.
№
| Parameter | Method for |
setting the parameter value | Parameter description |
Representation | Default value | Value range | |
1 | Identification number* | Automatically | Displays the identification number of the Display object in the digital |
video surveillance system |
with distributed architecture | Sequence of numbers | - | Depends on the number of the Display objects in the digital |
video surveillance system |
with distributed architecture | ||
2 | Name* | Enter the value |
into the |
field |
Sets the name of the Display object in the digital |
video surveillance system |
with distributed architecture | Latin, Cyrillic and service characters |
Display | A line containing a sequence of any |
characters (letters, digits, service characters |
except > and < |
characters), |
case- |
insensitive. Number of |
characters—from 1 to 60 |
3 | Disable |
Is identified by the check mark
Set the checkbox | Sets the state |
(enabled or disabled) of the Display object in the digital |
video surveillance system |
with distributed architecture | Boolean type |
Not available
Clear | Set—the |
Display object is disabled and |
isn't used Clear—the Display object |
is enabled and used | ||||||
The Computers group | ||||||
4 | Select an element* |
Set the checkbox | Contains a list of computers ( |
Server, Remote Administrator |
's workstation, Remote |
workstation) connected to the given |
Server (Remote Administrator |
's workstation). The |
checkboxes corresponding to the computers |
determine whether or not the computers should display the Monitor objects |
created on the basis on the given Display object |
Boolean type |
Not available
Clear | Set—the selected |
computer will display the Monitor object |
created on the basis of the given Display object |
Clear—the selected computer will not display the Monitor object |
created on the basis of the given Display object |
5 | Computer | Automatically |
Sets the computer name in the local network |
Computer name in the local network | Computer name in the local network | Depends on the number of objects in the local network. A line containing a sequence of any |
characters (letters, digits, service characters except > and < characters), |
case- |
insensitive. Number of |
characters—from 1 to 60 |
6 | Name | Automatically |
Sets the name to the computer |
in the digital |
video surveillance system with distributed architecture | Name of the Computer object registered in the system | Name of the Computer object registered in the system | Depends on the number of objects in the digital |
video surveillance system |
with distributed architecture A line containing a sequence of any |
characters (letters, digits, service characters except > and < characters), |
case- |
insensitive. Number of |
characters—from 1 to 60 |
*The name Name of the element is not isn't displayed in the settings panel of the given object.