The Display object is designed to register virtual screens in the system, which are used as a basis for interface components created in the Axxon PSIM system. The settings panel of the Display object is shown in the figure.

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Display object.

 

Parameter

Method for entering the parameter

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Display object in the digital distributed video surveillance system.

Sequence of numbers

-

Depends on the number of Display objects in the digital distributed video surveillance system.

2

Name*

Enter the value in the box

Defines the name of the Display object in the digital distributed video surveillance system.

Latin, Cyrillic and service characters

Screen

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Is identified by the check mark

Defines the condition of the Display object (enabled or disabled) in the digital distributed video surveillance system.

Boolean type

Not available

Yes – the Display object is disabled and is not in use

No – the Display object is enabled and is in use.

Computer Group

4

Select an element*

Is identified by the check mark

Contains a list of computers (videoserver, Remote Administrator Workstation, Remote Workstation) connected to the given videoserver (Remote Administrator Workstation).

The check marks referred to the computers define whether or not the computers should display the Monitor objects based on the given Display object.

Boolean type

Not available

Yes – the computer will display the Monitor object, created on the basis of the given Display object.

No – the computer will not display the Monitor object, created on the basis of the given Display object.

5

Computer

Automatically

Defines the computer name in the local network.

Computer name in the local network

Computer name in the local network

Depends on the number of objects in the local network.

A line containing a sequence of any symbols (letters, digits, service characters), not case-sensitive

Number of symbols – from 1 to 60.

6

Name

Automatically

Gives the name to the computer used in the digital distributed video surveillance system

Name of the Computer object registered in the system

Name of the Computer object registered in the system

Depends on the number of objects in the digital distributed video surveillance system. 

A line containing a sequence of any symbols (letters, digits, service characters), not case-sensitive

Number of symbols – from 1 to 60.

*The name of the element is not displayed in the settings panel of the given object.