Go to documentation repository
To provide operation of distributed system operation, you must configure the interaction between Servers, Remote Admin Workstations Administrator’s workstations and Remote Clients interactions are to be configured. . The interaction between Servers, Remote Admin Workstations Administrator’s workstations and Remote Clients interaction means database replication (for Servers and Remote Admin Workstations Administrator’s workstations only) and event exchange. For During configuration, you must specify for each Server, Remote Admin Workstation and Remote Administrator’s workstation and Remote Client the lists of interacting and non-interacting Servers, Remote Admin Workstations and Administrator’s workstation and Remote Clients are to be created.
Configuration You can configure the interaction of the surveillance system interaction is performed from the administering components from administration Server or, if there are dedicated subnets, from the node Server or Remote Admin WorkstationAdministrator’s workstation.
To configure the interaction between the distributed system components, do the following:
The Computer column displays the list of network names of Servers, Remote Admin Workstations Administrator’s workstations and Remote Clients registered in the the Hardware tab (2). In the Computer column, left-click the network name of the Server, Remote Admin Workstation Administrator’s workstation or Remote Client to change its interaction settings. Text in the selected cell becomes grey.
Info | ||
---|---|---|
| ||
To search for a computer by name, use the Ctrl+F hotkeys combinationkeyboard shortcut. The The Search in tree window will be opened window opens, enter the full computer name or its part in it and click press the Enter button. Found computer will be is highlighted in grey in the list. |
In the IP address column, specify the addresses of the computers you are connecting to (4). Features:
By default, you must specify the IP address
. If
the DNS instead of IP allowed checkbox is set
on the settings panel of
the Security zone object in the Programming tab,
you can specify DNS name
instead of IP address.
If computer addresses in the network are set automatically (DHCP is configured),
then you can leave the IP address
field blank.
title | Note |
---|
If the specified IP address must be set for all communications connections with this computer in the distributed system, right-click in the the IP address field and select Replace links from <Computer name> to with <IP-address> in connections in the opened feature menu (5). This is allowed if computers with one network interface are used in the distributed system and the specified IP address is to must be used to communicate with these computers.
Note | ||
---|---|---|
| ||
When clicking the Apply button you click the Apply button (see step 10), the changes will be are saved only for the current computer. In order for the IP address to be saved for all computers in the distributed system, click the the Apply button holding button pressing down the the Ctrl key on the keyboard. |
If the box next the checkbox in the Connection column and in the row , corresponding to the Server, Remote Admin Workstation or Remote Administrator’s workstation or Remote Client is checkedset, then the data on system configuration of the selected Server, Remote Admin Workstation or Administrator’s workstation or Remote Client with any Server, Remote Admin Workstation Administrator’s workstation or Remote Client is exchanged (65). To forbid prohibit exchange of configuration data with the selected Server, Remote Admin Workstation or Administrator’s workstation or Remote Client, set clear the checkbox in the the Connection column unchecked column.
Info | ||
---|---|---|
| ||
Server or Remote Admin Workstation always Administrator’s workstation always exchange configuration parameters with Remote Client, even if the Connection checkbox is unchecked clear for this Remote Client. |
If the box next to the checkbox in the Send events column and in the row , corresponding to the Server or Remote Admin Workstation is checkedAdministrator’s workstation is set, then events are exchanged between selected Server or Remote Admin Workstation and Administrator’s workstation and any Server or Remote Admin Workstation (7Administrator’s workstation (6). To forbid prohibit event exchange with the selected Server, Remote Admin Workstation Administrator’s workstation or Remote Client, set clear the checkbox in the the Send event column unchecked.
Info | ||
---|---|---|
| ||
Server or Remote Admin Workstation always Administrator’s workstation always exchange configuration parameters with Remote Client, even if the the Send events checkbox checkbox is unchecked clear for this Remote Client. |
Info | ||
---|---|---|
| ||
In order to set all checkboxes in the Connection or Send events columns columns, highlight a box cell in the required column and click press Ctrl+A. To set clear all the checkboxes unchecked, highlight a box cell and click press Shift+A. |
...
Let’s consider setup of a Server and Remote Client connection via video gate videogate as an example. A diagram of interaction of relevant components is shown in the figure.
Info | ||
---|---|---|
| ||
Videogate is used in large distributed video surveillance systems for routing the video signals among servers and clients (or administrator workstations used as operator workstations) between Servers and Clients located in different subnetworks. See For details, see General information on the videogate for details. |
According to the diagram, shown in the figure above, interaction must be disabled between the server (SERVER1) Server and Remote Client (MN1). As a result, the Architecture tab is to display the settingsdisplays the following configuration parameters:
In Axxon PSIM, the Computer object corresponding to the The Remote Client (MN1) Computer object in isn't displayed on the Hardware tab in the of the System settings dialog box on the server (SERVER1) will not be displayed in the Axxon PSIM software packagewindow.
However, if the you set the Send events checkbox is set (the Connection checkbox is to be deselectedclear), the Computer object corresponding to the Remote Client (MN1) will be is displayed on the Hardware tab on the Server (SERVER1) tab , but it will be is marked with and the icon and the object name will be is highlighted by in grey color. This indicates It means that administering administration of the given object is forbidden.