Go to documentation repository
To provide distributed system operation, Servers, Remote Admin Workstations and Remote Clients interactions are to be configured. Servers, Remote Admin Workstations and Remote Clients interaction means database replication (for Servers and Remote Admin Workstations only) and event exchange. For each Server, Remote Admin Workstation and Remote Client lists of interacting and non-interacting Servers, Remote Admin Workstations and Remote Clients are to be created.
Configuration of the surveillance system interaction is performed from the administering Server or, if there are dedicated subnets, from the node Server or Remote Admin Workstation.
To configure the interaction between the distributed system components, do the following:
The Computer column displays the list of names of Servers, Remote Admin Workstations and Remote Clients registered in the Hardware tab (2). In the Computer column left click the name of the Server, Remote Admin Workstation or Remote Client to change its interaction settings. Text in the selected cell becomes grey.
Note
To search computer by name use Ctrl+F hotkeys combination. The Search in tree window will be opened, enter the full computer name or its part in it and click the Enter button. Found computer will be highlighted in grey in the list.
In the IP address column, specify the addresses of the computers you are connecting to (4). By default, the IP address is to be specified. If the DNS instead of IP allowed checkbox is set checked on the settings panel of the Security zone object in the Programming tab, then DNS name can be specified instead of IP address. If computer addresses are set automatically (DHCP is configured), then IP address field can be left blank.
Note
If the specified IP address is to be set for all communications with this computer in the distributed system, right-click in the IP address field and select Replace links from <Computer name> to <IP-address> in the opened feature menu (5). This is allowed if computers with one network interface are used in the system and the specified IP address is to be used to communicate with these computers.
Important!
If the box next the Connection column and the row, corresponding to the Server, Remote Admin Workstation or Remote Client is checked, then the data on system configuration of the selected Server, Remote Admin Workstation or Remote Client with any Server, Remote Admin Workstation or Remote Client is exchanged (6). To forbid exchange of configuration data with the selected Server, Remote Admin Workstation or Remote Client, set the checkbox in the Connection column unchecked.
Note
If the box next to the Send events column and the row, corresponding to the Server or Remote Admin Workstation is checked, then events are exchanged between selected Server or Remote Admin Workstation and any Server or Remote Admin Workstation (7). To forbid event exchange with the selected Server, Remote Admin Workstation or Remote Client, set the checkbox in the Send event column unchecked.
Note
Note
Interaction of the distributed video surveillance system components is now configured.
Let’s consider setup of a Server and Remote Client connection via video gate as an example. A diagram of interaction of relevant components is shown in the figure.
Note.
Videogate is used in large distributed video surveillance systems for routing the video signals among servers and clients (or administrator workstations used as operator workstations) located in different subnetworks. See General information on the videogate for details.
According to the diagram, shown in the figure above, interaction must be disabled between the server (SERVER1) and Remote Client (MN1). As a result, the Architecture tab is to display the settings:
The Remote Client (MN1) Computer object in the Hardware tab in the System settings dialog box on the server (SERVER1) will not be displayed in the Axxon PSIM software package.
However, if the Send events checkbox is set (the Connection checkbox is to be deselected), the Computer object corresponding to the Remote Client (MN1) will be displayed on the Hardware tab on Server (SERVER1) tab but it will be marked with
and the object name will be highlighted by grey color. This indicates that administering of the given object is forbidden.