Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

When the INTELLECT ™ software is started with the Axxon PSIM is launched with a key and equipment limit exceeded object limit, there is the message with the name of object because of which the limit is exceeded , the Limit exceeded message is displayed in the loading window indicating the object which caused the excess and the number of objects created in the "created/ permittedallowed" format. The Square brackets indicate the internal ID of the object type in the license key is shown in square brackets.

Image RemovedImage Added

In this case to start the INTELLECT ™ Axxon PSIM software operation, do the following:

  1. Forward the intellectpsim.sec key from the INTELLECT Axxon PSIM directory to another folder, e.g. “D"D:\Temp”Temp".
  2. Run the INTELLECT ™ Axxon PSIM software in a demo the Demo mode.
  3. Remove a redundant object.
  4. Shutdown the INTELLECT ™ Axxon PSIM software.
  5. Restore the key from the “D"D:\Temp” Temp" folder to the INTELLECT Axxon PSIM installation directory.
  6. Start the INTELLECT ™ Axxon PSIM software.

If you try to add an the object that is not provided by the license key, there , then it will not be possible to add it to the equipment tree, since it will be the message that current system configuration does not allow more than 1 object of this type.

Image Removed

absent in the Create object function (see The Create object function). Similarly, it will not be possible to create another object if the limit on the number of such objects provided by the license key is reached.

Moreover time of action of certain objects can be set in the intellectpsim.sec license key. If the action of the objects expired, Intellect Axxon PSIM starts as usual, but the expired object is colored red in the hardware tree, and the INVALID_OBJECT_TIME event from this object comes to the Debug window.

Image RemovedImage RemovedImage AddedImage Added

After the expiration of the object, it is impossible to use it in Intellect Axxon PSIM: it continues to be displayed in the object tree, but events are not received from it and it does not respond. Other modules cannot communicate with an expired object.

To resume work use of with an expired object, connect ITV|AxxonSoft Manager in order to update the intellectyou need to request the psim.sec license key from the AxxonSoft manager and update it. If the object is no longer requiredneeded, it you can be deleted delete it (see Deleting).

Info
title

...

Note

The validity period of the object

...

cannot be longer than the validity period of the temporary key.