Go to documentation repository
The Failover service object is used to ensure the operation of the distributed system in the failover mode.
The settings panel of the Failover service object is shown in the figure.
Description of Table describes the setting parameters relevant corresponding to the elements on of the settings panel of theFailover service object is given in table.
№
| Parameter
| Method for setting the parameter value | Parameter description |
Representation | Defaultvalue | Value range |
1 | Monitor PC | Select |
the value from the list | Sets the name of the Server the state of which |
will be monitored by the object | Names of the Computer objects registered in the system | - | Depends on the number of the Computer objects registered in the system | |||
2 | Speed of object transfer to monitoring computer (rpm) | Enter the value into the field | Sets the speed of transferring objects in case the connection is lost. This setting is necessary so that the failover server sends messages at a certain speed and the receiving server has time to process them. The transfer speed should be set depending on the network speed, server bandwidth, etc. | Sequence of numbers | 1000 | From 0 and above |
3 | Wait for reconnection ( |
s) |
Enter the value |
into the field | Sets the time period |
in seconds |
after which the configuration will be transferred to the backup Server after the loss of connection | Sequence of numbers | - | From 0 to 65535 |
4 | Time left __ days | Automatically |
Displays the period of time |
in days |
remaining |
to restore the configuration from the backup Server to the main Server and |
restore the license | Days | 0.00 | From 0.00 to 50.00 |
5 | Transfer if no ping | Set the checkbox | Specifies if it is necessary to transfer the configuration without the ping from the main monitored Server |
Boolean type |
Clear |
Set—the configuration is transferred if there is no ping |
Clear—ping isn't taken into account |
when transferring the configuration |
6 | Type | Select |
the value from the list | Sets the object type in the configuration of the monitored Server |
that |
should be transferred to the backup Server in case of connection |
loss | Types of objects registered on the |
basis of the main Server | - | Depends on the configuration created on the |
basis of the main Server |
7 | Number | Select |
the value from the list | Sets the |
identifier of the object of the selected type that |
should be transferred to the backup Server in case of connection |
loss |
Identifiers of the objects of the selected type that are present in the configuration of the monitored Server |
- | Depends on the number of the objects of the selected type in the configuration of main Server |
8 | Name | Automatically | Sets the name of the object |
that |
should be transferred to the backup Server in case of connection |
loss | Names of the objects of the selected type that are present in the configuration of the monitored Server |
- | Depends on the configuration created on the |
basis of the main Server |
9 | Range | Click the button | Opens the dialog box for |
the complex selection of |