You can add create IP devices in bulk by importing their parameters from a CSV file.
...
Create a CSV file with devices listed as follows:
Code Block IP address, Port, Vendor, Model, Login, Password, Identifier, Object name, Latitude, Longitude, Azimuth, Archive name, Recording mode
NoteNote title Attention! - For each added camera, three parameters are required: IP address, Vendor and Model.
- The parameters that aren't specified will be automatically set to
- their default
- values.
- Even if no additional parameters are set
Info - , you must still include commas.
- All parameters are case-sensitive.
title - To separate the integer and fractional parts in coordinates, use a point.
- If there is a comma in the device model name, in order not to violate the logic of the CSV file, it is necessary to add the \ character before the comma in the model name.
Example: the device model name is CO-i20DY2(2,7-9) (CO-YUC-HM96-279). In the CSV file, it is necessary to specify the model name as CO-i20DY2(2\,7-9) (CO-YUC-HM96-279).
For example:
Code Block 10.0.12.245, 80, Bosch, Dinion IP starlight 8000 MP, service, Admin12345!, 1441, Camera 1, 0, 0, 0, Archive AliceBlue, Always 10.0.12.246,, Bosch, Dinion IP starlight 8000 MP,,,,,,,,, 10.0.12.247, 80, Bosch, Dinion IP starlight 8000 MP,,,, Camera 3,,, Archive AliceBlue, On motion
infoNote title Attention! The vendor and model of the device must be specified exactly as in the list of supported devices.
title Note For correct display of the object name in Axxon One VMS, the CSV file must be UTF-8 BOM or UTF-32 BOM encoded.
- Drag & drop Upload the created file to the field in using the Drag&Drop method in one of the following ways:
using the IP Device Discovery Wizard in Axxon One.
- using the form for adding CSV files.
Info | ||
---|---|---|
| ||
|
The specified devices will be added to the configuration.