The Control panel object is designed used to register and configure a specialized control panel used for to manage the PTZ control devices in the Axxon PSIM™ systemPSIM.

The settings panel of the Control panel object is shown in the figure.

Table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols usedRepresentation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Control panel object in the digital  distributed digital video surveillance system .Sequence of numberswith the distributed architecture

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Control panel objects in the digital distributed video surveillance system with the distributed architecture

2

Name*

Enter the value in into the field

Defines Sets the name of the Control panel object in the digital distributed video surveillance system .with the distributed architecture

Latin, Cyrillic characters and service characters

Control panel

A line containing a sequence of any symbols characters (letters, digits, service characters apart from except > and < symbolscharacters), not case-sensitiveinsensitive.

Number of symbols – charactersfrom 1 to 60.

3

Disable

Is identified by the check mark

Set the checkbox

Sets the state Defines the condition of the Control panel object (enabled or disabled) in the digital distributed video surveillance system .with the distributed architecture

Boolean type

Not available

Clear

SetYes – the Control panel object is disabled and is not is disabled and isn't used

Clear in useNo – the Control panel object is enabled and is in use.used

4

Telemetry controllerController

Select the value Is selected from the list

Defines Sets the Telemetry Controller parent Telemetry controller object of the digital distributed video surveillance systemsystem with the distributed architecture, to which the given Control panel object refers.belongs

Name of the Telemetry controllerController objects registered in the system

Name of the Telemetry Controller parent Telemetry controller object.

Depends on the number of Telemetry controller objects telemetry controllers in the digital distributed video surveillance system with the distributed architecture

The Settings Groupgroup

5

Port

Is selected Select the value from the list

Defines Sets the number of the computer serial (COM) port of the computer, to which used to connect the Control panel will be connected.

List of available COM ports availableports 

COM1

Depends on the number of COM ports in on the video server Server or Remote Administrator Workstation.'s workstation

6

Speed

Is selected Select the value from the list

Defines Sets the data communication rate for speed of the serial (COM) port.

Kb/secs


9600

From 300 to 256000.

7

Parity

Is selected Select the value from the list

Defines Sets the parity check mode for the data transmission over the serial (COM) port.

List of the parity check modes.

None

Even, Odd, None, Mark, Space.

8

DTR

Is identified by the check mark.

Set the checkbox

Sets Defines, whether or not the power should be supplied to the control Control panel via the DTA COM port.the output of the DTR serial (COM) port

Boolean type

YesSet

YesSetthe power will be supplied via the DTR port .outputNo

Clearthe power will not be supplied via the DTR port .output

9

RTS

Is identified by the check mark.

Set the checkbox

Sets Defines, whether or not power should be supplied to the control Control panel via the output of the RTS serial (COM) port.

Boolean type

YesSet

YesSetthe power will be supplied via the RTS port .output

NoClearthe power will not be supplied via RTS port .output

10

Priority

Is selected Select the value from the list

Defines priorities for control Sets the priority of the PTZ units devices control using the Control panel.

Names of priorities used to control the PTZ units.devices

Low

Control prohibited the PTZ unit device cannot be controlled using the Control panel.

Low the given PTZ device can be controlled no sooner than when the PTZ with after it is controlled by the devices with the standard or high priorities has been controlled.priority

Standard the given PTZ device can be controlled no sooner than when the PTZ with high priority has been controlled.

High – the PTZ with the given priority will                         be controlled first.

controlled after it is controlled by the device with the high priority

Highthe PTZ device is controlled first

*Name *The name of the element is not displayed in the settings panel of the given object.