Go to documentation repository
The Control panel object is designed used to register and configure a specialized control panel used for to manage the PTZ control devices in the Axxon PSIM™ systemPSIM.
The settings panel of the Control panel object is shown in the figure.
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.
№
| Parameter | Method for setting the parameter value | Parameter description | Symbols usedRepresentation | Default value | Value range | ||
1 | Identification number* | Automatically | Displays the identification number of the Control panel object in the digital distributed digital video surveillance system .Sequence of numberswith the distributed architecture | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Control panel objects in the digital distributed video surveillance system with the distributed architecture | ||
2 | Name* | Enter the value in into the field | Defines Sets the name of the Control panel object in the digital distributed video surveillance system .with the distributed architecture | Latin, Cyrillic characters and service characters | Control panel | A line containing a sequence of any symbols characters (letters, digits, service characters apart from except > and < symbolscharacters), not case-sensitiveinsensitive. Number of symbols – characters—from 1 to 60. | ||
3 | Disable | Is identified by the check mark | Set the checkbox | Sets the state Defines the condition of the Control panel object (enabled or disabled) in the digital distributed video surveillance system .with the distributed architecture | Boolean type | Not available | Clear | Set—Yes – the Control panel object is disabled and is not is disabled and isn't used Clear— in useNo – the Control panel object is enabled and is in use.used |
4 | Telemetry controllerController | Select the value Is selected from the list | Defines Sets the Telemetry Controller parent Telemetry controller object of the digital distributed video surveillance systemsystem with the distributed architecture, to which the given Control panel object refers.belongs | Name of the Telemetry controllerController objects registered in the system | Name of the Telemetry Controller parent Telemetry controller object. | Depends on the number of Telemetry controller objects telemetry controllers in the digital distributed video surveillance system with the distributed architecture | ||
The Settings Groupgroup | ||||||||
5 | Port | Is selected Select the value from the list | Defines Sets the number of the computer serial (COM) port of the computer, to which used to connect the Control panel will be connected. | List of available COM ports availableports | COM1 | Depends on the number of COM ports in on the video server Server or Remote Administrator Workstation.'s workstation | ||
6 | Speed | Is selected Select the value from the list | Defines Sets the data communication rate for speed of the serial (COM) port. | Kb/secs | 9600 | From 300 to 256000. | ||
7 | Parity | Is selected Select the value from the list | Defines Sets the parity check mode for the data transmission over the serial (COM) port. | List of the parity check modes. | None | Even, Odd, None, Mark, Space. | ||
8 | DTR | Is identified by the check mark. | Set the checkbox | Sets Defines, whether or not the power should be supplied to the control Control panel via the DTA COM port.the output of the DTR serial (COM) port | Boolean type | YesSet | Yes – Set—the power will be supplied via the DTR port .outputNo – Clear—the power will not be supplied via the DTR port .output | |
9 | RTS | Is identified by the check mark. | Set the checkbox | Sets Defines, whether or not power should be supplied to the control Control panel via the output of the RTS serial (COM) port. | Boolean type | YesSet | Yes – Set—the power will be supplied via the RTS port .output No – Clear—the power will not be supplied via RTS port .output | |
10 | Priority | Is selected Select the value from the list | Defines priorities for control Sets the priority of the PTZ units devices control using the Control panel. | Names of priorities used to control the PTZ units.devices | Low | Control prohibited – —the PTZ unit device cannot be controlled using the Control panel. Low – —the given PTZ device can be controlled no sooner than when the PTZ with after it is controlled by the devices with the standard or high priorities has been controlled.priority Standard – —the given PTZ device can be controlled no sooner than when the PTZ with high priority has been controlled. High – the PTZ with the given priority will be controlled first. controlled after it is controlled by the device with the high priority High—the PTZ device is controlled first |
*Name *The name of the element is not displayed in the settings panel of the given object.