The Control panel object is designed to register and configure a specialized control panel used for PTZ control in the Axxon PSIM™ system.

The settings panel of the Control panel object is shown in figure.

Table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Control panel object in the digital  distributed video surveillance system.

Sequence of numbers

-

Depends on the number of Control panel objects in the digital distributed video surveillance system

2

Name*

Enter the value in the field

Defines the name of the Control panel object in the digital distributed video surveillance system.

Latin, Cyrillic and service characters

Control panel

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

Disable

Is identified by the check mark

Defines the condition of the Control panel object (enabled or disabled) in the digital distributed video surveillance system.

Boolean type

Not available

Yes – the Control panel object is disabled and is not in use

No – the Control panel is enabled and is in use.

4

Telemetry controller

Is selected from the list

Defines the parent Telemetry controller object of the digital distributed video surveillance system, to which the given Control panel object refers.

Name of the Telemetry controller objects registered in the system

Name of the parent Telemetry controller object.

Depends on the number of Telemetry controller objects in the digital distributed video surveillance system

Settings Group

5

Port

Is selected from the list

Defines the number of the COM port of the computer, to which the Control panel will be connected.

List of COM ports available

COM1

Depends on the number of COM ports in the video server or Remote Administrator Workstation.

6

Speed

Is selected from the list

Defines the data communication rate for the COM port.

Kb/sec


9600

From 300 to 256000.

7

Parity

Is selected from the list

Defines the parity check mode for the data transmission over the COM port.

List of parity check modes.

None

Even, Odd, None, Mark, Space.

8

DTR

Is identified by the check mark.

Defines, whether or not power should be supplied to the control panel via the DTA COM port.

Boolean type

Yes

Yes – the power will be supplied via the DTR port.

No – the power will not be supplied via the DTR port.

9

RTS

Is identified by the check mark.

Defines, whether or not power should be supplied to the control panel via the RTS COM port.

Boolean type

Yes

Yes – the power will be supplied via the RTS port.

No – the power will not be supplied via RTS port.

10

Priority

Is selected from the list

Defines priorities for control of the PTZ units using the Control panel.

Names of priorities used to control PTZ units.

Low

Control prohibited – the PTZ unit cannot be controlled using the Control panel.

Low – the given PTZ can be controlled no sooner than when the PTZ with standard or high priorities has been controlled.

Standard – the given PTZ can be controlled no sooner than when the PTZ with high priority has been controlled.

High – the PTZ with the given priority will                         be controlled first.

*The name of the element is not displayed in the settings panel of the given object.