The Operator query panel object is the interface frame used to perform user specified functions with a user's and contains a custom set of elements. The elements are configured by the Axxon PSIM administrator in using the ArpEdit utility (see the User's Manual for ArpEdit ). The  

The settings panel of the Operator query panel object is shown in the figure.

Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Operator query panel object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols usedRepresentation

Default value

Value range

1

Identifier*

Enter the value in into the field

File name designed for used to control certain PTZ unit controldevice. The filename file name is usually the same as the name of the PTZ unit.device

Latin, Cyrillic and service characters

-

A line containing a sequence of symbols characters (Latin and service characters, digits), not case-sensitiveinsensitive.

Number of symbols – charactersfrom 1 to 16.

2

Name*

Enter the value in into the field

Defines Sets the name of the the Operator query panel object in the digital distributed video surveillance system with the distributed architecture.

To ensure user friendliness, the The object name is usually given the same name as the name of the PTZ unit.device

Latin, Cyrillic and service characters

Operator query panel

A line containing a sequence of symbols characters (Latin and service characters apart from , digits, except > and < symbols, digitscharacters), not case-sensitiveinsensitive.

Number of symbols – charactersfrom 1 to 60.16

3

Disable

Is identified by the check mark

Set the checkbox

Sets the state (enabled or disabled) of the Defines the status of the Operator query panel object (enabled or disabled).

Boolean type

Not available

Clear

Set—the Yes – the Operator query panel object is disabled and is not in use.No – the isn't used

Clear—the Operator query panel object is enabled and is in use.used

4

Computer

Is selected Select the value from the list

Defines Sets the Computer parent Computer object of the digital distributed video surveillance systemsystem with the distributed architecture, to which the given given Operator query panel object refers.belongs

Name of the Computer objects registered in the system

Name of the Computer parent Computer object.

Depends on the number of the Computer objects in the digital distributed video surveillance system with the distributed architecture

5

Allow moving

Is identified by the check mark.Set the checkbox

Allows moving the Operator query panel over  around the screen using the mouse.

Boolean type

Not available

Clear

Set—moving Yes – movement is allowed.

No – movement is prohibited.

Clear—moving isn't allowed

The Settings groupSettings Group

6

X

Enter the value in into the field.

Defines Sets the coordinate in the horizontal X horizontal axis for of the upper left corner of the the Operator query panel on the screen.

% of the screen width.

Not defined

From 0 to M*100, where M is the number of surveillance monitors the installed .Video Monitors

7

Y

Enter the value in into the field.

Defines Sets the coordinate in the vertical Y vertical axis for of the upper left corner of the the Operator query panel on the screen.

% of the screen height.

Not defined

From 0 to M*100, where M is the number of surveillance monitors the installed .Video Monitors

8MonitorIs selected Select the value from the listSets the number of the computer monitor number, for which the to which coordinates are assignedsetSequence of numbers11 to 161–16

9

Type

Is selected Select the value from the list

Defines Sets the object type for displaying that calls the Operator query panel.

Types of the objects registered in the system

Not defined

Depends on the number of the object types of objects created in the digital distributed video surveillance system .with the distributed architecture

10

Number

Is selected Select the value from the list

Defines Sets the number of the object for displaying that calls the Operator query panel.

Sequence of numbers

Not defined

Depends on the number of  of the objects created in the digital distributed video surveillance system .with the distributed architecture

11

Name

Automatically

Defines Sets the name of the object for displaying that calls the Operator query panel.

Names of the objects of the  the selected type registered in the system

Not defined

Depends on the number of the objects types created in n the digital distributed video surveillance system .with the distributed architecture

12

Event

Is selected Select the value from the list

Defines Sets the name of the event , after which that calls the Operator query panel is displayed

Types Names of events the event types for the given types selected type of devices.

EmptyEmpty –

the Empty—the Operator query panel is not displayed. isn't called

List of the available events depends on the selected object.

*The name Name of the element is not isn't displayed in the settings panel of the given object.