The Operator query panel object is the interface frame used to perform user specified functions with a user's set of elements. The elements are configured by the Axxon PSIM administrator in the ArpEdit utility (see the User's Manual for ArpEdit ). The settings panel of the Operator query panel object is shown in figure.

Table describes the parameters of the settings corresponding to the elements of the settings panel of the Operator query panel object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identifier*

Enter the value in the field

File name designed for certain PTZ unit control. The filename is usually the same as the name of the PTZ unit.

Latin, Cyrillic and service characters

-

A line containing a sequence of symbols (Latin and service characters, digits), not case-sensitive

Number of symbols – from 1 to 16.

2

Name*

Enter the value in the field

Defines the name of the Operator query panel object in the digital distributed video surveillance system.

To ensure user friendliness, the object name is usually given the same name as the name of the PTZ unit.

Latin, Cyrillic and service characters

Operator query panel

A line containing a sequence of symbols (Latin and service characters apart from > and < symbols, digits), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Is identified by the check mark

Defines the status of the Operator query panel object (enabled or disabled).

Boolean type

Not available

Yes – the Operator query panel object is disabled and is not in use.

No – the Operator query panel object is enabled and is in use.

4

Computer

Is selected from the list

Defines the parent Computer object of the digital distributed video surveillance system, to which the given Operator query panel object refers.

Name of the Computer objects registered in the system

Name of the parent Computer object.

Depends on the number of Computer objects in the digital distributed video surveillance system

5

Allow moving

Is identified by the check mark.

Allows moving the Operator query panel over the screen using the mouse.

Boolean type

Not available

Yes – movement is allowed.

No – movement is prohibited.

Settings Group

6

X

Enter the value in the field.

Defines the coordinate in the X horizontal axis for the upper left corner of the Operator query panel on the screen.

% of the screen width.

Not defined

From 0 to M*100, where M is the number of surveillance monitors installed.

7

Y

Enter the value in the field.

Defines the coordinate in the Y vertical axis for the upper left corner of the Operator query panel on the screen.

% of the screen height.

Not defined

From 0 to M*100, where M is the number of surveillance monitors installed.

8MonitorIs selected from the listSets the computer monitor number, the to which coordinates are assignedSequence of numbers11 to 16

9

Type

Is selected from the list

Defines the object type for displaying the Operator query panel.

Types of the objects registered in the system

Not defined

Depends on the number of types of objects created in the digital distributed video surveillance system.

10

Number

Is selected from the list

Defines the number of the object for displaying the Operator query panel.

Sequence of numbers

Not defined

Depends on the number of  objects created in the digital distributed video surveillance system.

11

Name

Automatically

Defines the name of the object for displaying the Operator query panel.

Names of the objects of the  selected type registered in the system

Not defined

Depends on the number of objects types created in the digital distributed video surveillance system.

12

Event

Is selected from the list

Defines the event, after which the Operator query panel is displayed

Types of events for the given types of devices.

Empty

Empty – the Operator query panel is not displayed.

List of available events depends on the selected object.

*The name of the element is not displayed in the settings panel of the given object.