Go to documentation repository
...
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Telemetry Controller object in the digital video surveillance system with the distributed architectureSequence of numbers | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Telemetry Controller objects in the igital video surveillance system with the distributed architecture |
2 | Name* | Enter the value into the field | Sets the name of the Telemetry Controller object in the digital video surveillance system with the distributed architecture | Latin, Cyrillic characters and service characters | Telemetry Controller No. | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state of the Telemetry Controller object (enabled or disabled) in the digital video surveillance system with the distributed architecture | Boolean type | Clear | Set—the Telemetry Controller object is disabled and isn't used Clear—the Telemetry Controller object is enabled and is used |
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture, to which the given Telemetry Controller object belongs | Name of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the digital system with the distributed architecture |
The Settings group | ||||||
5 | Controller type* | Select the value from the list | Sets the data communication protocol with the PTZ device via the serial (COM) port. Data communication protocols are supplied by the PTZ devices manufacturers | Name of the PTZ devices integrated in the system | Videotec | Corresponds to the list of the PTZ devices integrated in the system |
6 | Port | Select the value from the list | Sets the number of the computer COM port, used to connect the PTZ devices | List of the available COM ports | COM1 | Depends on the number of COM ports on the Server or Remote Administrator’s workstation. If a non-null value is selected, then the local COM port has a higher priority than other devices when processing the PTZ device commands. Otherwise, the COM port priority is set by default |
7 | Rate | Select the value from the list | Sets the data communication rate via the COM port | kB/s | 9600 | From 300 to 256000 |
8 | Parity | Select the value from the list | Sets the parity check mode for the data transfer via the COM port | List of parity check names and modes | None | Even, Odd, None, Mark, Space |
9 | DTR | Set the checkbox | Sets the power supply to the PTZ device via the output of the DTR COM port | Boolean type | Set | Set—the power will be supplied via the DTR port output Clear—the power will not be supplied via the DTR port output |
10 | RTS | Set the checkbox | Sets the power supply to the PTZ device via the output of the RTS COM port | Boolean type | Set | Set—the power will be supplied via the RTS port output Clear—the power will not be supplied via the RTS port output |
...