Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

The settings panel of the SIP-panel object is shown in the pictures below.

The description of the SIP-panel interface object is shown in the table.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
The Position group

1


The X field

Type-in the value in the field

Sets the coordinate in the X horizontal axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The Y field

Type-in the value in the field

Sets the coordinate in the Y vertical axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

2


The W field

Type-in the value in the field

Sets the window width of the SIP-panel interface object

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The H field

Type-in the value in the field

Sets the window height of the SIP-panel interface object

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

3The Monitor dropdown listSelect in the listSets the system ID of the monitor for which the coordinates are setIDs of the monitors in the OS1From 1 to 16

The Basic settings tab

Table describes the parameters of the Basic settings tab.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
1The Terminal drop-down listSelect in the listSets the SIP-terminal object which SIP-devices use the SIP Panel.Name of the SIP Panel objects registered in the system-Depends on the number of the SIP Panel objects in the system
2The Monitor drop-downSelect in the listSets the the Monitor object corresponding to the Video Surveillance Monitor to which the video cameras associated with the corresponding SIP-devices are added.Name of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system

The Advanced settings tab

Table describes the parameters of the Advanced settings tab.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
The Interface behavior group

1

The Display only when calling checkbox

Set the checkbox

Enables displaying of the SIP-panel interface box only at call

Boolean type

No

Yesthe SIP panel is only displayed during call.

Nothe SIP panel is always displayed.

2The New calls to the end check boxSet the checkboxEnables adding new calls to the end of the list.Boolean typeNo

Yes – new calls are added to the end of the list.

No – new calls are added to the top of the list.

3The Disable keypress sound check boxSet the checkboxMutes the sound of keys clicked on the SIP panelBoolean typeNo

Yes – keypress sound disabled.

No – keypress sound is turned on.

4The Maximize screen on call check boxSet the checkboxEnables automatic display switching on callBoolean typeNoYeswhen a call is made to the SIP terminal corresponding to the SIP panel, the Display to which the SIP panel is added is automatically shown.

No – the displays are not switched automatically on any call to the SIP terminal corresponding to the SIP panel.

5The Calls to unknown users checkboxSet the checkbox

Enables the option to call unknown subscribers

Note. Unknown user is a number that is present in the SIP-terminal, but not in the address book of the current SIP-operator.

Boolean typeYes

Yes - calls to unknown subscribers are allowed

No - calls to unknown subscribers are prohibited

The Interface elements group
6The Dial pad check boxSet the checkboxEnables the display of the dial pad in the interfaceBoolean typeYes

Yes - the dial pad is displayed.

No - the dial pad is hidden.

The Caption check boxSet the checkboxEnables the display of tab names in the interface. When disabled, only the Call tab will be displayed without displaying the nameBoolean typeYes

Yes - the tab names are displayed.

No - only the Call tab is displayed without displaying the name.

The Archive check boxSet the checkboxEnables the display of the Archive tab in the interfaceBoolean typeYes

Yes - the Archive tab is displayed.

No - the Archive tab is hidden.

The Call control buttons check boxSet the checkboxEnables the display of the buttons at the bottom of the call control panelBoolean typeYes

Yes - call control buttons are displayed.

No - call control buttons are hidden.

The Operator settings tab

Table describes the parameters of the Operator settings tab.

ParameterMethod for specifying the parameterParameter descriptionPresented asDefault valueRange of values

1

The Operators tableIs selected in the columnSets the list of SIP-operators who can work with this SIP-panel---
The Number columnIs selected in the listSelecting a SIP-operator identifierIdentifiers of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
The Subscriber columnIs selected in the listSelecting a SIP-operator numberNumbers of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
The Name columnIs selected in the listSelecting a SIP-operator name in Axxon PSIMNames of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
2The All buttonClick the buttonAdds all existing operators to the table---
3The Range buttonClick the buttonOpens the Add operators window to add multiple operators---
4The Default drop-down listIs selected in the listSets the default SIP-operator.-Select on start
  • Select on start - when you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time, you will be logged in under the previously selected SIP-operator.

  • User rights - the SIP-panel will be logged in under the SIP-operator that is linked to the Axxon PSIM user rights. There should be the registration in Axxon PSIM with the rights of the corresponding user.

  • SIP operator from the list - the SIP panel will be logged in under the selected SIP-operator. Depends on the number of SIP-operator objects in the system.

  • No labels