Unable to render embedded object: File (books.jpg) not found.
Go to documentation repository
Documentation for Auto Intellect 5.0. Documentation for other versions of Intellect is [available too].
Traffic violations detection module object settings panel contains the following interface elements (Figure 8.13 1, Table 8.13—1).
Figure 8.13 1 Traffic violations detection module object settings panel
Table 8.13—1 Traffic violations detection module object settings description
№ |
Parameter name |
Parameter setting method |
Description |
Data type |
Default value |
Value range |
---|---|---|---|---|---|---|
1 |
«Traffic lights signal» dropdown list |
Selecting the value in the list |
Selecting «Sensor/Detector» object, by signal of which traffic light is detected |
List of accessible «Sensor/Detector» objects |
no |
Depending on number of accessible «Sensor/Detector» objects |
2 |
«Draw a stop line» check box |
Setting check box |
Draw a stop line on video in front of traffic light function activation |
Boolean type |
no |
Yes – drawing a stop line function is active |
3 |
«Stop line settings» button |
Clicking |
Access to stop line settings |
- |
- |
- |
4 |
«Delay in violation registering » field |
Setting the value in the field |
Set period after which the running a red light or stop will be considered as a violation |
Millisecond |
1000 |
0-20000 |
5 |
«The number of frames to save» field |
Setting the value in the field |
Set the number of frames to save in the database while the running a red light |
Whole nonnegative number |
2 |
From 1 to infinity |
6 |
«Frame saving interval» field |
Setting the value in the field |
Set frame saving interval while the running a red light |
Millisecond |
500 |
0-20000 |
7 |
"Type of violation" drop-down list |
Selecting the value in the list |
Selecting the type of traffic violation that will be specified in the capture to the alarm when the Stop violation is registered |
List of available violation types while the stopping – Stop over stop line or Stop over crosswalk line |
Stop over stop line |
- |
8 |
«The number of frames to save» field |
Setting the value in the field |
Set the number of frames to save in the database when the Stop violation is registered |
Whole nonnegative number |
2 |
From 1 to infinity |
9 |
«Frame saving interval» field |
Setting the value in the field |
Set frame saving interval when the Stop violation is registered |
Millisecond |
500 |
0-20000 |