Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Contents

 

Intellect base

XML fileParameterAvailable valuesDefaultProduct versionParameter in effect
<Archive storage drive>:\VIDEO\Settings.xmlRotateAngle0, 90, 180, 2700 

Sets the rotation angle of video image in the archive. If the rotation angle is specified in the video camera settings (see Configuring a rotation angle of video image), then this parameter is set automatically in Settings.xml file.

In Axxon player the archive is rotated at the specified angle when being played back or exported.
C:\ProgramData\elasticsearch-2.0.1\config\elasticsearch.ymlhttp.port0 - 655369200up to Intellect 4.10.2

The parameter sets the port occupied by Elastic Search search engine. The value is to be the same as one specified in the cam_title.run.config file (see below).

C:\ProgramData\elasticsearch-5.2.2\config\elasticsearch.ymlIntellect 4.10.3 and later
<Intellect instalation>\Modules\cam_title.run.configElasticSearchPort0 - 655369200 The parameter sets the port Intellect sends data for Elastic Search search engine to. The value is to be the same as one specified in the elasticsearch.yml file (see above).

 

Intellect Web Report System

XML fileParameterAvailable valuesDefaultProduct versionParameter in effect
<Directory of the Intellect software installation>\Modules\Wt2\Web.configCamMonitorShift-5000 - 50000 

Sets shifting of video start while report viewing in milliseconds:

>0 – video will start later than time specified in a report

<0 – video will start earlier than time specified in a report

FaceReplaceCameraIpFromIP-address-up to 3.2Changes internal IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside
FaceReplaceCameraIpToIP-address-up to 3.2Changes external IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside
WorkThroughGatewaytrue, falsefalsefrom 3.3Enables receiving video from Gateway while viewing video for POS reports and for "Face" module report. A Gateway is selected authomatically.

FACE-Intellect

XML fileParameterAvailable valuesDefaultParameter in effect
<Directory of the Intellect software installation>\Modules\face_client.run.configProblemImagesPath to a folderNone

Path to the folder for storing images which haven't been added to the database is specified in the parameter value. The specified folder will be created automatically.

Note.

If %USER% is specified in the parameter value, the images which haven't been added to the database will be stored in the folder:

c:\Users\%LOGGED_USER%\AppData\Local\AxxonSoft\FaceIntellect\ProblemImages\