The settings panel of the Charts object is shown in the figure.

The description of the Charts interface object settings is shown in the table.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
The Filters tab

1

The Identification number field

Automatically

Shows the identification number of the Charts object in the system

Positive integer

-

Depends on the number of Charts objects in the system

2

The Name field

Type-in the value in the field

Assigns the name to the Charts object

Latin, Cyrillic and service characters

Display manager

A line containing a sequence of any symbols (letters, digits, service, characters apart from > and < symbols), non case-sensitive

Number of symbols – from 1 to 60

3

The Disable checkbox

Set the chechbox

Shows the status (enabled or disabled) of the Charts object in the system

 

Boolean type

No

Yes – the Charts object is disabled and is not in use

No – the Charts object is enabled and is in use

4

The Display dropdown list

Select from the list

Assigns the parent Display object, to which the given Charts object refers

Name of the Display objects registered in the system

Name of the parent Display object

Depends on the number of the Display objects in the system

5

 

The X filed

Type-in the value in the field

Sets the coordinate in the X horizontal axis for the upper left corner of the Charts interface object on the screen

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The Y field

Type-in the value in the field

Sets the coordinate in the Y vertical axis for the upper left corner of the Charts interface object on the screen

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

6


The W filed

Type-in the value in the field

Sets the window width of the Charts interface object

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The H field

Type-in the value in the field

Sets the window height of the Charts interface object

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

7The X buttonClick the buttonOpens a sample box to set the Charts window position on the screen.---

8

The Allow moving checkbox

Chechbox is set

Allows manual moving of the Charts interface box

Boolean type

No

Yesmanual moving is allowed.

Nomanual moving is prohibited.

9The Monitor dropdown listSelect in the listSets the system ID of the monitor for which the coordinates are setIDs of the monitors in the OS1From 1 to 16
10The Number drop-down listSelect in the listSets the Analog sensor object IDs, which readings should be displayed on the chartPositive integer-

Depends on the Analog sensor objects in the system.

11The Name fieldAutomaticallySets the name of the Analog sensor object, which readings should be displayed on the chart
Names of the Analog sensor objects-Depends on the object type
12The Color drop-down listSelect in the listSets the color to highlight the corresponding analog sensor on the graph in the Charts windowColor paletteBlackRGB color

13

The Number of pixels fieldType-in the value in the fieldSets the number of pixels to be displayed on the graphSequence of numbers0>=0