Go to documentation repository
Documentation for Auto Intellect 5.6. Documentation for other versions of Intellect is available too.
Previous page Next page
Traffic violations detection module object settings panel contains the following interface elements:
The following table describes the elements of the Traffic violations detection object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Traffic lights signal dropdown list | Selecting the value in the list | Selecting «Sensor/Detector» object, by signal of which traffic light is detected | List of accessible «Sensor/Detector» objects | no | Depending on number of accessible «Sensor/Detector» objects |
2 | Alarm direction dropdown list | Selecting the value in the list | Selecting the signal of traffic light detection on which the traffic violations detection is to be responded | List of accessible directions | Basic | Basic - use the basic signal of the traffic light Left - use the left arrow of the traffic light Right - use the right arrow of the traffic light |
3 | Draw a stop line checkbox | Setting check box | Draw a stop line on video in front of traffic light function activation | Boolean type | no | Yes – drawing a stop line function is active |
4 | Stop line settings button | Clicking | Access to stop line settings | - | - | - |
5 | Setting violation areas button | Clicking | Access to stop line settings | - | - | - |
6 | Delay in violation registering field | Setting the value in the field | Set period after which the running a red light or stop will be considered as a violation | Millisecond | 1000 | 0-99999 |
7 | Time of stop for recording field | Setting the value in the field | Set period that determines the time interval during which the vehicle should stay still while registering the Stop over crosswalk line violation | Millisecond | 3000 | 0-99999 |
8 | Add.photos: field | Setting the value in the field | Set the number of photos made before the licence plate fixing and after its going out the control zone | Whole nonnegative number | 2 | 0-99 |
9 | Interval: field | Setting the value in the field | Set period that determines the time interval between saving additional photos | Millisecond | 1000 | 0-99999 |
10 | Number of pictures to trace alarm: field | Setting the value in the field | Specifying number of photos which will be stored from the moment of LP recognizing on the base recognizer to the moment of LP recognizing on the additional recognizer | Whole nonnegative number | 3 | 0-99 |
Additional recognizers table | ||||||
11 | LPR channel column | Selecting the value in the field | Selecting the additional LPR channel if it's required to use additional recognizers along with the base recognizer | List of accessible "LPR channel" objects | - | Depending on number of accessible LPR channel objects |
Sensor column | Selecting the value in the field | Selecting sensor from which events about traffic light operation will be received | List of accessible "Sensor" objects | - | Depending on number of accessible Sensor objects | |
State column | Selecting the value in the field | Selecting event from the sensor on which violation will be fixed | - | - | Active (оn) – sensor is closed Normal (оff) – sensor is opened | |
тAlarm type column | Selecting the value in the field | Selecting type of violation which will be fixed in result of joint operation of additional and base recognizers | - | - | Marking violation Red light violation |