Documentation for ATM Intellect 12.0. Documentation for other versions of ATM Intellect is available too.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

On page:

General information

The status bar shows the number of non-ignored objects (OB) and the number of objects that have hardware failures (HF) shown at the moment.

The status bar also shows the start of the displayed period for the current cell column (CC), time when the data was last loaded into the database (LD), functioning rate (FR%) and non-functioning rate (NR%) for the video surveillance system, broken down by reason (see the Ignoring objects section).

Important!

The rates are not calculated if the Alarms, Failures or Disconnected filter is enabled – see The number of alarms displayed at the Log panel.

Functioning and non-functioning rates

The status bar shows the functioning rate (FR%) and non-functioning rate (NR%) for the video surveillance system, broken down by reason.
FR(%) is calculated according to the following formula:
(1-Nnf/Na)*100, where

  • Nnf is the number of objects that do not function properly.
  • Na is the total number of objects

The non-functioning rate for a particular reason is calculated according to this formula:
(Nnfbr/Na)*100, where

  • Nnfbr is the number of objects that do not function properly for this particular reason
  • Na is the total number of objects

These rates are calculated only for non-ignored objects. For ignored objects, these rates are never calculated and the filter is never used. If a non-functioning rate has the value of zero, it is not shown in the status bar.

  • No labels