Documentation for Axxon Next 4.5.0 - 4.5.10. Documentation for other versions of Axxon Next is available too.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 101 Next »

Before you install Axxon Next:

  • Make sure all Servers are connected to an uninterruptible power supply (UPS).
  • To prevent frequent system updates, which can cause system inoperability, it is recommended to use Windows 10 LTSB or Windows Server (see Operating system requirements).
  • Install all the latest Windows service/update packs.
  • Synchronize the system time with world time and specify the correct time zone.
  • For each Server, specify a unique Windows hostname.
  • Specify a new password for the account of local administrator.
  • Synchronize the time of all Servers and IP devices.
  • Create another administrator account for backup. Specify a password for it.

Axxon Next installation (see Installation, Update):

Antivirus configuration (see Appendix 4. Using Axxon Next with anti-virus software):

  • Add the following processes to the exclusion list:

    1. consul.exe;
    2. nomad.exe;
    3. apphost.exe;
    4. postgres.exe.
  • Add the following folders to the exclusion list:
    1. C:\ProgramData\AxxonSoft\AxxonNext;
    2. C:\Program Files\AxxonSoft\AxxonNext;
    3. C:\Program Files\Common Files\AxxonSoft;
    4. Postgres and metadata folders if they are not default.
  • Add the following ports to the exclusion list:
    1. 20109-20210;
    2. 4000 (only for Failover installation type);
    3. 4646-4648 (only for Failover installation type);
    4. 8300-8302 (only for Failover installation type);
    5. 8500 (only for Failover installation type);
    6. 8600 (only for Failover installation type).

Initial setup:

Camera configuration (see The Video Camera Object):

  • Connect the cameras to the Servers.
  • Synchronize the time of all Servers and cameras with a single NTP server.
  • Add the cameras to the system (see Adding and removing IP devices, Bulk creation of IP devices). Preferred protocol: ONVIF generic.
  • Multistreaming:

    1. Make sure that for each camera different stream IDs are selected as High quality and Low quality streams.

    2. Low quality stream settings should be lower than the High quality stream.
  • Codec type*: H.265 or H.264 is recommended. If you plan to use the Web Client, then H.264 is recommended since using H.265 leads to the stream recompression on the Server side.
  • FPS: the Low quality stream frame rate should be at least 6 to ensure the correct operation of the detection tools.
  • Resolution:
    1. Aspect ratio should be the same for Low and High quality streams*.
    2. The Low quality stream resolution should be no less than 640x360 and no more than 1280x720 to ensure the correct operation of the detection tools.
  • Bitrate: 
    1. Recommended type*: VBR.

    2. Set maximum bitrate / bandwidth limitation.

    3. Recommended bitrate: 1 mbps per 1 MP.

  • GOV (also known as GOP, I Frame, etc.): it is recommended to have at least one keyframe per second. 

    *May differ for different camera models.

Archive recording configuration (see Binding a camera to an archive):

  • Link each camera to at least one archive.
  • Configure recording to the archive (permanent or triggered by detection tools) for each camera.
  • Make sure pre-recording is enabled (> 1 sec).

  • Note that after you re-create the archive, it is necessary to re-create all recording rules in the detection tool settings or Programming settings.

Detection tool configuration (see Configuring detection tools):

  • The motion detection tool should operate on a low quality stream (see Configuring VMD).
  • Configure masking (exclude areas) of the frame areas which constantly trigger motion detection (for example, on-screen display (OSD) or TV).
  • Create automatic rules for recording to the archive (see Automatic Rules).
  • Use a NVIDIA GPU for the detection tools operation if there is one.

Automatic notifications (see Configuring Macros):

Users and roles (see Configuring user permissions):

Backups (see Backing up a configuration):

  • Create a new backup:
    1. After you complete the system configuration.
    2. Before you update to a new version.
    3. After you update to a new version.
    4. Periodically (recommended period is 1 month).
  • To restore the configuration, use the backup created on the same version of software (see Restoring a configuration). Example: if backup was created on v. 4.3 then restore it only on v. 4.3; if you also need to update to 4.5 then first restore it on 4.3 and then update to 4.5.

Web Client (see Working with Axxon Next Through the Web Client):

  • Do not use H.265 in camera settings since it causes the stream recompression on the Server side. It is recommended to use H.264 for such cameras.
  • Change the HTTP port from 80 to a custom port (see Configuring the web server).

System check:

  • Monitor the CPU load (<= 60%).
  • Monitor the RAM load (<= 60%).
  • Monitor the disk load:
    1. Active time is lower than 50%.
    2. Average response time is lower than 1 sec.

  • Monitor free disk space: system drive has not less than 20 GB.
  • Use the statistics panel in Web client (see Viewing Camera and Archive Statistics).
  • No labels