Configure the main parameters of the Incident manager as follows:

  1. Go to the the Main tab of the Incident manager object settings panel.
  2. In the Chief interfaces list (1), set the checkboxes opposite other Incident manager objects to which the operator can escalate events.
  3. In the Data server field (2), enter the address of the server to which the data about the operator's actions in the Incident manager should be sent.

    Attention!

    This feature is not available in the current Intellect version.

  4. Set the Allow closing without processing checkbox (3) to enable the operator to close the events in the Incident manager without processing them.
  5. If necessary, set a hotkey, using which the operator can start processing the event. To do this, place the mouse cursor in the "In work" hotkey field (4) and press the required key or key combination on the keyboard.
  6. From the Map drop-down list (5), select the previously created Map object, which will be linked with the Incident manager. The operator can make the object with the event be highlighted on the map.
  7. From the Video drop-down list (6), select a video display mode:
    1. ActiveX - archive and live video will open in a separate window.
    2. Monitor - archive and live video will open on the selected Surveillance Monitor. In this case, the Surveillance Monitor will operate in the Active camera mode, regardless of the corresponding setting - see Configuring the display mode for camera boxes.
  8. In the Column width field (7), set the width of the columns in the event handling interface in pixels or as a percentage of the entire width of the Incident manager interface. Percentage values ​​should be set in fractions of 1, for example, 0.25. If a value greater than 1 is specified, then it will be taken in pixels. The default column width is 150 pixels.
  9. Click the Apply button.