This function allows broadcasting intellect.sec, the key file, governing the system configuration, to all PCs which have the distributed digital video surveillance and audio monitoring system. If the system functional has been updated and a new key file was received, it should be updated in all system PCs, using the Send key to all function.
This function is accessible only from the context menu of the Computer object, corresponding to the given local computer, which performs administrator functions.
Note
If an updated key file is not broadcast in due time to all system computers, the Intellect system will not get started, when the PC is switched on, since the key file data will not match the information contained in the database.
If the key is successfully applied on a particular computer in the distributed system, the "Key updated" message is displayed in the Event Vewer. However, if the key has expired or the number of objects in the key is less than that created in the object tree on the corresponding computer, then this information is not displayed in the Event Vewer, but an error occurs the next time Intellect starts. See also Features of the Axxon PSIM software operation when the object limit is exceeded and What should I do if I'm getting the ‘key file expired’ error when running?
If the license key cannot be applied on a computer due to the HID codes mismatch, the message "Key rejected (HID incompliance)" will be displayed in the Event Viever. See also What should I do if I'm getting the ‘Key file is not corresponding cards’ error when running?