Documentation for ACFA PSIM

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

The system settings of the Virdi controller are set up as follows:

  1. From the Authentication mode drop-down list (1), select the mode of authentication and controller operation:
    • Server / Terminal - the decisions are made by the Server, and if it is not available, then by the controller.
    • Terminal / Server - the decisions are made by the controller, and if it is not available, then by the Server.
    • Server - the decisions are made by the Server.
    • Terminal - the decisions are made by the controller.
    • Offline mode - the offline mode of the controller.

      Note

      In the offline mode, the controller cannot be managed from the ACFA-Intellect Server.

  2. From the Antipassback drop-down list (2), select the double-entry control mode:
    • Local - the antipassback is controlled by the controller.
    • Server - the antipassback is controlled by the Server.
  3. From the Card format 1 and Card format 2 drop-down lists (3), select the format for displaying the access cards data:
    • Default - standard.
    • Hexademical - hexadecimal.
    • Decimal - decimal.
    • 3:5 Decimal - 3 or 5 decimal digits.
  4. Select the Enable force arming check box (4) if it is necessary to enable the forced arming of the zone, even if the zone has open doors.
  5. Select the Enable time synchronization check box (5) if it is necessary to enable the time synchronization on the Server and controller.
  6. Select the Enable end of line resistors check box (6) if it is necessary to enable the terminal resistors.
  7. Select the Enable logging (egress btn) checkbox (7) if it is necessary to log all events by clicking the EXIT buttons.
  8. Select the Enable interlocking on locks check box (8) if it is necessary to activate the dual locking of all doors.
  9. Click the Apply button (9) to apply the settings.

The system settings of the Virdi controller are set up.

  • No labels