The settings panel of the SIP-operator object is shown in the pictures below.
Table describes the parameters of the SIP-operator system object.
№ | Parameter | Method for setting the parameter value | Description | Presented as | Default value | Range of values |
1 | The Number field | Automatically | Sets the identification number for calls | Sequence of numbers | - | >=0 |
2 | The Bind operator to user rights checkbox | Is set with a checkbox | Enables binding of a SIP-operator to Axxon PSIM user rights. Activates the User drop-down list. Note. It is used when the User rights are selected by default on the operator's SIP panel. | Yes - binding of a SIP-operator to Axxon PSIM user rights is enabled No - binding of a SIP-operator to Axxon PSIM user rights is disabled | ||
3 | The User drop-down list | Is selected in the list | Sets the user under which it is necessary to register in Axxon PSIM. | Name of the User objects registered in the system. | Depends on the number of the User objects in the system. | |
4 | The Device priority drop-down list | Is selected in the list | Sets the priority of a call from this operator in the incoming calls window of the SIP panel. | Sequence of numbers | No | 0 – 10 The lower the number, the higher the priority and, accordingly, the higher the display in the list. If the field is left blank, then the priority is considered to be minimal. Calls from operators with the same priority will be sorted by the time of the call. |
The Server connection tab (only for SIP client terminal type)
Table describes the parameters of the Server connection tab.
№ | Parameter | Method for setting the parameter value | Description | Presented as | Default value | Range of values |
1 | The Login field | Enter the value in the field | Sets the username for connecting to the SIP-server | Latin, Cyrillic letters and service characters | - | A line representing a sequence of any symbols (letters, numbers, service symbols) |
2 | The Password field | Enter the value in the field | Sets the password for connecting to the SIP-server | Latin, Cyrillic letters and service characters | - | A line representing a sequence of any symbols (letters, numbers, service symbols) |
The Address book tab
Table describes the parameters of the Address book tab.
№ | Parameter | Method for setting the parameter value | Description | Presented as | Default value | Range of values |
1 | The Address books table | Is selected in the column | Sets the list of address books, the numbers of which should be available for this SIP-operator | - | - | - |
The Number column | Is selected in the list | Selecting the address book identifier | Identifiers of Address book objects registered in the system | - | Depends on the number of Address book objects in the system | |
The Name column | Is selected in the list | Selecting the name of the address book in Axxon PSIM | Names of Address book objects registered in the system | - | Depends on the number of Address book objects in the system | |
2 | The All button | Click the button | Adds all existing address books to the table | - | - | - |
3 | The Range button | Click the button | Opens the Add address books window to add multiple address books | - | - | - |